Abstract:Objective: Fractional Flow Reserve (FFR) is regarded as a fundamental index to assess pulmonary artery stenosis. The application of FFR can increase the accuracy of detection of pulmonary artery stenosis. However, the invasive examination may carry a number of physiological risks for patients. Therefore, we propose a personalized pulmonary circulation model to non-invasively calculate FFR of pulmonary artery stenosis. Methodology: We have employed a personalized pulmonary circulation model to non-invasively calculate FFR. This model combines boundary condition estimation and 3D pulmonary artery morphology reconstruction for CFD simulation. Firstly, we obtain patient-specific boundary conditions by matching cardiac output and main pulmonary artery pressure. Secondly, the 3D pulmonary artery morphology is reconstructed by semi-automatic segmentation. The CFD simulation is performed to obtain the pressure distribution in the entire pulmonary artery. Finally, the FFR in pulmonary artery stenosis is calculated as the ratio of distal pressure and proximal pressure. Results: To validate our model, we compare the simulated FFR with the measured FFR by pressure guide wires examination of 20 patients. The FFR simulated by our model shows a good agreement with the measured FFR by pressure guide wires examination (<span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.502ex" height="1.676ex" style="vertical-align: -0.338ex;" viewBox="0 -576.1 1507.8 721.6" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-72" x="0" y="0"></use> <use xlink:href="#MJMAIN-3D" x="729" y="0"></use></g></svg></span> 0.989, <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.712ex" height="2.176ex" style="vertical-align: -0.671ex; margin-left: -0.089ex;" viewBox="-38.5 -647.8 1598.3 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-70" x="0" y="0"></use> <use xlink:href="#MJMAIN-3C" x="781" y="0"></use></g></svg></span> 0.001). Conclusion: Our proposed personalized pulmonary circulation model is shown to be capable of non-invasively calculating FFR with sufficient accuracy. Significance: The FFR calculated by our personalized circulation model may effectively contribute to non-invasive detection of pulmonary artery stenosis and to a comprehensive evaluation of the entire pulmonary artery vascular tree.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-72" d="M21 287Q22 290 23 295T28 317T38 348T53 381T73 411T99 433T132 442Q161 442 183 430T214 408T225 388Q227 382 228 382T236 389Q284 441 347 441H350Q398 441 422 400Q430 381 430 363Q430 333 417 315T391 292T366 288Q346 288 334 299T322 328Q322 376 378 392Q356 405 342 405Q286 405 239 331Q229 315 224 298T190 165Q156 25 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 114 189T154 366Q154 405 128 405Q107 405 92 377T68 316T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMAIN-3D" d="M56 347Q56 360 70 367H707Q722 359 722 347Q722 336 708 328L390 327H72Q56 332 56 347ZM56 153Q56 168 72 173H708Q722 163 722 153Q722 140 707 133H70Q56 140 56 153Z"></path><path stroke-width="1" id="MJMATHI-70" d="M23 287Q24 290 25 295T30 317T40 348T55 381T75 411T101 433T134 442Q209 442 230 378L240 387Q302 442 358 442Q423 442 460 395T497 281Q497 173 421 82T249 -10Q227 -10 210 -4Q199 1 187 11T168 28L161 36Q160 35 139 -51T118 -138Q118 -144 126 -145T163 -148H188Q194 -155 194 -157T191 -175Q188 -187 185 -190T172 -194Q170 -194 161 -194T127 -193T65 -192Q-5 -192 -24 -194H-32Q-39 -187 -39 -183Q-37 -156 -26 -148H-6Q28 -147 33 -136Q36 -130 94 103T155 350Q156 355 156 364Q156 405 131 405Q109 405 94 377T71 316T59 280Q57 278 43 278H29Q23 284 23 287ZM178 102Q200 26 252 26Q282 26 310 49T356 107Q374 141 392 215T411 325V331Q411 405 350 405Q339 405 328 402T306 393T286 380T269 365T254 350T243 336T235 326L232 322Q232 321 229 308T218 264T204 212Q178 106 178 102Z"></path><path stroke-width="1" id="MJMAIN-3C" d="M694 -11T694 -19T688 -33T678 -40Q671 -40 524 29T234 166L90 235Q83 240 83 250Q83 261 91 266Q664 540 678 540Q681 540 687 534T694 519T687 505Q686 504 417 376L151 250L417 124Q686 -4 687 -5Q694 -11 694 -19Z"></path></defs></svg>
engineering, biomedical
What problem does this paper attempt to address?