Impedance plethysmography in the diagnosis of asymptomatic deep vein thrombosis in hip surgery: a venography-controlled study

Giancarlo Agnelli, Benilde Cosmi, Valeria Ranucci, Cinzia Renga, Stefano Mosca, Luciano Lupattelli, Paolo Di Filippo, Emanuele Rinonapoli, Giuseppe G Nenci
1991-11-01
Abstract:We prospectively evaluated the accuracy of computerized impedance plethysmography (CIP) in the diagnosis of asymptomatic deep vein thrombosis (DVT) in 246 consecutive high-risk patients scheduled for hip surgery, with bilateral venography used for comparison. The CIP was performed as a surveillance program every third day. If the CIP remained negative, bilateral venography was performed on postoperative day 10±1 or on day of treatment 14±1 in nonoperated-on patients. If the CIP became positive, venography was performed within 24 hours. The sensitivity and specificity of CIP for proximal and distal DVT were 19% (confidence interval [CI], 13% to 24%) and 91% (CI, 87% to 94%), respectively. The positive and negative predictive values were 52% (CI, 38% to 65%) and 70% (CI, 65% to 74%), respectively. The sensitivity and specificity of CIP for proximal DVT were 24% (CI, 13% to 34%) and 90% (CI, 87 …