Numerical study of a composite cooling method for hypersonic aircraft

Bohong Chen,Xudong Tian,Shihe Yi
DOI: https://doi.org/10.1063/5.0189361
IF: 4.6
2024-01-01
Physics of Fluids
Abstract:Thermal protection is a crucial issue for a long-flying hypersonic aircraft. In this work, a composite cooling method is proposed and implemented on a hypersonic blunt cone. The composite cooling method combines impinging and convective cooling at the cone head with transpiration cooling employed downstream to produce an overall cooling effect of the cone. Using computational fluid dynamics, the influences of the cooling gas and different attack angles on the cooling effect are examined. The results indicate that the combined cooling method can effectively reduce the overall outer wall temperature of the cone. In particular, with the combined cooling method, an increase in mass flow rate of the cooling gas has been observed in numerical tests, which results in a decrease in the head temperature. The maximum temperature decrease can reach 77.0% on the wall when the mass flow rate of the cooling stream is 1.1 kg/m2 s. The cooling performance on the leeward side can be better than that on the windward side for a fixed cooling gas mass flow rate. This gap in cooling performance between the two sides can be further amplified by a larger attack angle. Quantitatively, when using the combined cooling method, the temperature difference between the windward and leeward sides increases from 106 to 270 K when the attack angle increases from 4° to 8°. The numerical results in this study could provide theoretical and statistical guidance for the design of novel active thermal protection methods for hypersonic aircraft.
mechanics,physics, fluids & plasmas
What problem does this paper attempt to address?