Louis Girardin,Catriona Stokes,Myat Soe Thet,Aung Ye Oo,Stavroula Balabani,Vanessa Díaz-Zuccarini
Abstract:Compliance mismatch between the aortic wall and Dacron Grafts is a clinical problem concerning aortic haemodynamics and morphological degeneration. The aortic stiffness introduced by grafts can lead to an increased left ventricular (LV) afterload. This study quantifies the impact of compliance mismatch by virtually testing different Type-B aortic dissection (TBAD) surgical grafting strategies in patient-specific, compliant computational fluid dynamics (CFD) simulations.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the study of the hemodynamic effects on patients of using vascular grafts of different lengths and compliances in Type - B aortic dissection (TBAD) surgeries. Specifically, the paper explores how the compliance mismatch between the vascular graft and the native aortic wall affects the patient's left ventricular afterload, pressure distribution, energy loss (EL), and endothelial cell activation potential (ECAP). The study tested different graft strategies in patient - specific computational fluid dynamics (CFD) simulations through virtual surgical strategies to quantify the effects of compliance mismatch.
### Research Background
- **Problem Definition**: Type - B aortic dissection is a cardiovascular disease involving a tear in the descending aorta. Surgical treatment usually involves replacing the damaged aortic segment with a Dacron graft. However, Dacron grafts are stiffer than native aortic tissue, resulting in a compliance mismatch, which may increase local aortic pressure and left ventricular afterload.
- **Clinical Significance**: Compliance mismatch may lead to pulse wave reflection and local pressure elevation, increasing energy loss, thereby increasing left ventricular mass and causing hypertrophy. In addition, an increase in aortic stiffness and pressure may also accelerate pulse wave velocity (PWV), increasing cardiovascular risks such as stroke.
### Research Methods
- **Data Acquisition**: CT angiography, Cine - MRI, and 2D - Flow MRI were used to obtain the patient's anatomical structure and blood flow dynamic data.
- **Virtual Surgical Intervention**: Three virtual surgical scenarios were created, using grafts of different lengths respectively: middle descending aorta (MDA), complete descending aorta (CDA), and total replacement of the thoraco - abdominal aorta (ETR). In addition, two compliant grafts (BC1 and BC2 +) were also simulated.
- **Computational Model**: ANSYS CFX 19.0 was used to solve the three - dimensional transient Navier - Stokes equations to simulate hemodynamic parameters such as pressure, wall shear stress (WSS), and energy loss (EL).
### Main Results
- **Pressure Changes**: As the length of the graft increases, the inlet pressure gradually rises, with the ETR case having the highest pressure. Using a compliant graft (BC1) can reduce the inlet pressure, but BC2 + has a higher compliance, resulting in a slight increase in pressure.
- **Pulse Wave Velocity (PWV)**: In cases where the graft is stiffer, PWV increased by up to 15.4%, while in BC2 + (the most compliant graft), PWV decreased by 7.4%.
- **Energy Loss (EL)**: Increasing aortic stiffness and graft length will increase energy loss. Using a compliance - matched graft (BC1) can reduce pulse pressure and energy loss.
- **Wall Shear Stress (WSS)**: The effect of compliance mismatch on WSS is most significant in the aneurysm area, with the maximum percentage differences being 16% (MDA) and 20% (CDA) respectively.
### Conclusions
- **Clinical Recommendations**: By minimizing the length of the graft and matching its compliance with that of the native aorta, the risk of left ventricular hypertrophy can be reduced and the patient's prognosis can be improved. This provides evidence for clinicians, indicating that using a compliance - matched graft may help improve the patient's treatment outcome.
### Keywords
- Type - B aortic dissection
- Computational fluid dynamics (CFD) simulation
- Dacron graft
- Virtual intervention
- Compliance mismatch
Through these research results, the paper provides an important reference for clinicians in choosing grafts, which helps optimize surgical strategies and improve the patient's treatment outcome.