Electrical rejuvenation of chronically implanted macroelectrodes in nonhuman primates

Kyle Patrick O'Sullivan,Mark E Orazem,Kevin J Otto,Christopher R Butson,Jonathan L Baker
DOI: https://doi.org/10.1088/1741-2552/ad5703
IF: 5.043
2024-06-12
Journal of Neural Engineering
Abstract:Objective. Electrodes chronically implanted in brain tissue undergo complex interface changes with time. These interface alterations can introduce inconsistencies that can undermine an electrode's recording and stimulation characteristics. Electrode-tissue interface (ETI) changes may be particularly problematic in applications of closed-loop neuromodulation, where electrode recordings are used as a control signal. Previous work has demonstrated the efficacy of short stimulating pulses ("electrical rejuvenation") for reducing the effect of chronic ETI changes in microelectrodes in rodents. Exploration of electrical rejuvenation methods in larger, clinically relevant electrode designs in nonhuman primates (NHP) would provide a useful baseline for potential development of clinical applications of the technique. Here, multiple variations of the electrical rejuvenation method were tested to explore potential parameters of optimization. Approach. Alternating-current (AC) and direct-current (DC) electrical rejuvenation methods were explored in 3 electrode types chronically implanted in 2 adult male rhesus-macaque NHP, including epidural electrocorticography (ECoG) electrodes and penetrating deep-brain stimulation (DBS) electrodes. EIS was performed before and after each rejuvenation, and at subsequent intervals to track the longevity of effects. Stochastic error modeling was performed to determine consistency of EIS data with Kramers-Kronig relations, to evaluate the signal to noise (SNR) characteristics and stability as a measurement system. Main results. AC and DC rejuvenation were found to be acutely effective on all tested electrode types, with DC and low-frequency AC producing the largest drops in impedance and reduction of observed tissue component. The effects of a single rejuvenation were found to last from several days to over 1 week, and all rejuvenation pulses were well tolerated by the animals with no observable changes to behavior or electrode integrity. Significance. These results demonstrate the efficacy of electrical rejuvenation for diminishing the impact of chronic ETI changes in nonhuman primates with clinically relevant macroelectrode designs.
engineering, biomedical,neurosciences
What problem does this paper attempt to address?