Polypyrrole merged zirconium-based metal-organic framework NU-1000 for detection of levodopa

Sudip Biswas,Yuling Chen,Yao Xie,Xin Sun,Yang Wang
DOI: https://doi.org/10.1007/s00604-020-04622-y
IF: 5.7
2020-11-17
Microchimica Acta
Abstract:A post-synthetic integration of polypyrrole onto NU-1000 MOF (PPy@NU-1000) was done by pyrrole adsorption, followed by oxidative polymerization. The synthesized materials were characterized by XRD, SEM, BET, and FTIR. The ultra-high specific surface area with high-density catalytic sites of NU-1000 (2223 m<sup>2</sup> g<sup>−1</sup>) was combined with the electrical conductivity of PPy (2–100 S cm<sup>−1</sup>). PPy@NU-1000 provides superior electrocatalytic activity and charge transfer properties compared to an individual component. The PPy@NU-1000-modified GCE was applied to detect the biomolecule Levodopa (LD). The DPV oxidation peak of LD was strongest at 272 ± 10 mV vs. Ag/AgCl reference electrode. Under the optimized experimental condition, the fabricated electrochemical sensor exhibited a wide quantification range of 0.005–70 μM with a sub-nanomolar detection limit of 0.0001 μM (S/N 3). The described sensor exhibits high sensitivity (2.08 μA μM<sup>−1</sup> cm<sup>−2</sup>) with reasonable stability, reproducibility, and selectivity for the detection LD in the presence of potentially interfering compounds. Furthermore, human serum analysis showed excellent recovery values within the range 99.3–101.6%. Validation of the method was performed against HPLC.
chemistry, analytical
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop an efficient, sensitive and selective electrochemical sensor for the detection of the biomolecule levodopa (LD). Specifically, the authors prepared a PPy@NU - 1000 composite material by coating polypyrrole (PPy) on the zirconium - based metal - organic framework (Zr - based Metal - Organic Framework, MOF) NU - 1000 and applied it to the detection of levodopa. ### Main research background 1. **Parkinson's Disease (PD)**: PD is a rapidly increasing neurodegenerative disease that causes symptoms such as movement disorders in patients. Levodopa is an important drug for the treatment of PD because it can cross the blood - brain barrier, while dopamine itself cannot. 2. **Detection of levodopa**: Abnormal levels of levodopa may lead to adverse reactions. Therefore, accurate and sensitive detection of levodopa is of great significance for the early diagnosis and treatment of PD. 3. **Existing detection methods**: Currently, commonly used levodopa detection methods include high - performance liquid chromatography (HPLC), spectrometry and electrochemical methods. Among them, the electrochemical method has attracted attention due to its advantages such as simple operation, low cost and fast response. ### Research objectives 1. **Improve the performance of the electrochemical sensor**: By combining the high conductivity of PPy and the high specific surface area and catalytic activity of NU - 1000, a composite material with excellent electrocatalytic activity and charge - transfer performance is prepared. 2. **Achieve high - sensitivity detection of levodopa**: Develop an electrochemical sensor capable of detecting levodopa in a wide concentration range (0.005 to 70 μM) and reach a detection limit at the sub - nanomolar level (0.0001 μM). 3. **Verify the practical application of the sensor**: Verify the reliability and accuracy of the sensor by analyzing human urine samples and compare it with the high - performance liquid chromatography (HPLC) method. ### Main achievements 1. **Material characterization**: Through means such as X - ray diffraction (XRD), scanning electron microscopy (SEM), and specific surface area analysis (BET), the successful synthesis of the PPy@NU - 1000 composite material was confirmed. 2. **Electrochemical performance**: Through cyclic voltammetry (CV) and differential pulse voltammetry (DPV) tests, it was confirmed that the glassy carbon electrode (GCE) modified with PPy@NU - 1000 has the highest electrocatalytic activity and charge - transfer ability. 3. **Practical application**: The recovery rate of the sensor in human urine samples is between 99.3% and 101.6%, showing good stability and reproducibility, and is highly consistent with the results of the HPLC method. In conclusion, this paper successfully developed a high - performance electrochemical sensor for levodopa by preparing the PPy@NU - 1000 composite material, providing a new tool for the early diagnosis and treatment of PD.