Experimental study on the effects of ignition location and vent burst pressure on vented hydrogen-air deflagrations in a cubic vessel

Shengchao Rui,Changjian Wang,Xinjiao Luo,Quan Li,Haoran Zhang
DOI: https://doi.org/10.1016/j.fuel.2020.118342
IF: 7.4
2020-10-01
Fuel
Abstract:<p>A series of experiments was conducted in a cubic vessel of <span class="math"><math>0.5×0.5×0.5m</math></span> to investigate the effects of ignition location and vent burst pressure<span class="math"><math>Pv</math></span>on vented stoichiometric hydrogen-air deflagrations inside and outside the vessel. The results show that two overpressure peaks resulting from the vent rupture and the flame-acoustic interaction respectively, were always found for front ignition. Another overpressure peak generated by the external explosion was observed for center ignition and<span class="math"><math>Pv&lt;69.8kPa</math></span>. For the back ignition, three overpressure peaks successively produced by the vent rupture, the flame venting and the external explosion were recorded for<span class="math"><math>Pv&lt;57.3kPa</math></span>. The maximum peak overpressure inside the vessel always increases with<span class="math"><math>Pv</math></span>, and the maximum peak overpressure for back ignition is significantly larger than those for front and center ignitions, and the latter two cases almost have the same values. The external overpressure-time curves present a single peak for front ignition and two peaks for back ignition. The external overpressure increases with<span class="math"><math>Pv</math></span>for front and back ignitions. However, the external overpressure increases for<span class="math"><math>Pv&lt;57.3kPa</math></span>, but it is insensitive to<span class="math"><math>Pv</math></span>as<span class="math"><math>Pv&gt;57.3kPa</math></span> for center ignition. The external flame speed increases with<span class="math"><math>Pv</math></span>for front ignition while it is independent of the latter for center and back ignitions. The maximum length of the external flame for back ignition is much larger than that for front ignition and slightly larger than that for center ignition.</p>
energy & fuels,engineering, chemical
What problem does this paper attempt to address?