Determination of gaseous carbonyl compounds by their pentafluorophenyl hydrazones with gas chromatography/mass spectrometry

Jian Li, Yan Li Feng, Chun Juan Xie, Juan Huang, Jian Zhen Yu, Jia Liang Feng, Guo Ying Sheng, Jia Mo Fu, Ming Hong Wu
2009-03-02
Abstract:A sensitive and reliable method has been developed for the simultaneous determination of 20 airborne carbonyl compounds in the C1–C10 range. The carbonyls were collected onto solid sorbent coated with pentafluorophenyl hydrazine (PFPH), followed by solvent extraction and gas chromatographic (GC)/mass spectrometric (MS) analysis of the PFPH derivatives. The sorbent is packed into two separate sections in a glass sampling tube. The two-section design allows convenient checking of collection efficiency and breakthrough. The sampling tube, with a coating amount of 971nmol PFPH per 100mg Tenax TA and operated at a sampling flow rate of 80mLmin−1, collects the 20 carbonyls with efficiencies above 95%. Hexane extracts the collected carbonyls in their PFPH derivatives in the sampling tube with better than 95% extraction efficiency. It is necessary to let the sampling tube sit at ambient temperature for …
What problem does this paper attempt to address?