Comparison of patient specific implant reconstruction vs conventional titanium mesh reconstruction of orbital fractures using a novel method
Andrei Krasovsky,Ahmad Hija,Nidal Zeineh,Tal Capucha,Dr Amir Haze,Omri Emodi,Adi Rachmiel,Dekel Shilo
DOI: https://doi.org/10.1016/j.jcms.2024.02.002
IF: 3.192
2024-02-06
Journal of Cranio-Maxillofacial Surgery
Abstract:Purpose To compare the reconstruction of orbital fractures using patient-specific implants (PSI) and conventional pre-formed titanium mesh; to develop a method of three-dimensional (3D) superimposition and analysis of the reconstructed orbits; and to present the pitfalls in 3D planning of orbital PSI and how to avoid them. Material and methods This was a retrospective study of patients with orbital fractures who were treated in our institution between the years 2022 and 2023 using PSI or conservative prefabricated titanium mesh. Three different methods for virtual reconstruction of orbital fractures were used and are detailed with advantages, disadvantages and indications. Data acquired included age, gender, method of reconstruction, functional outcomes and esthetic outcomes. 3D analysis for accuracy of reconstruction was performed. Results A total of 23 patients were included; 12 were treated using PSI and 11 using prefabricated titanium meshes. There were 8 male and 4 female patients in the PSI group comparted to 5 and 6 in the prefabricated group. All three virtual methods for reconstruction were used successfully, each with the proper indications. When comparing PSI reconstruction to conventional mesh, a significant difference in accuracy was observed; PSI cases showed an inaccuracy of 0.58 mm compared to 1.54 mm with the conventional method. Complications are presented, and tips for avoiding them are detailed. Conclusions Three different methods for virtual reconstruction were used successfully; automated computerized reconstruction is used for small defects, repositioning is the superior method for non-comminuted cases while mirroring is the method of choice in comminuted fractures. 3D analysis can be performed using a novel method detailed in this report. PSI reconstruction showed superior results, indicating it should be the method of choice when possible. Pitfalls are presented and approaches to prevent them are discussed. Orbital reconstruction is a very important entity in maxillofacial surgery with crucial functional and esthetical implications, and one should use virtual planning and PSI implants, as they significantly improve outcomes.
dentistry, oral surgery & medicine,surgery