Abstract:Graphene transistor sensors, with advantages such as facile surface functionalization and high sensitivity, have gained extensive research interest in gas detection applications. This study fabricated back-gated graphene transistors and employed a hydroxylation scheme for the surface functionalization of graphene. On the basis of the interaction mechanisms between gas molecules and graphene's electrical properties, a compact electrical kinetics model considering the gas-solid surface reaction of graphene transistors is proposed. The model can accurately predict the electrical kinetic performance and can be used to optimize sensor characteristics. The bias condition of a higher response can be rapidly determined. In addition, the density of hydroxyl groups on graphene is revealed to be the direction of improvement and a key factor of response. Hence, the gas detection capacity of sensors with varying densities of hydroxyl groups was assessed concerning ammonia gas, and design technology co-optimization (DTCO) is realized. Measurement results show that the sensor with 70 s of hydroxylation time has a 7.7% response under 22 ppm ammonia gas.