Robotic Ultrasound and Novel Collagen Analyses for Polycystic Kidney Disease Research Using Mice

Caroline R Sussman,Heather L Holmes,Alison Stiller,Ka Thao,Adriana V Gregory,Deema Anaam,Ryan Meloche,Yaman Mkhaimer,Harrison H Wells,Luiz D Vasconcelos,Matthew W Urban,Slobodan I Macura,Peter C Harris,Timothy L Kline,Michael F Romero
DOI: https://doi.org/10.34067/KID.0000000000000542
2024-08-12
Kidney360
Abstract:Background: 3D imaging and histology are critical tools for assessing polycystic kidney disease ( PKD ) in patients and animal models. Magnetic resonance ( MR ) imaging provides micron resolution, but is time consuming, expensive, and access to equipment and expertise is limiting. Robotic ultrasound ( US ) imaging has lower spatial resolution but is faster, more cost effective, and accessible. Similarly, Picrosirius red ( PSR ) staining and brightfield microscopy is commonly used to assess fibrosis; however, alternative methods have been shown in non-kidney tissues to provide greater sensitivity and more detailed structural characterization. Methods: In this study, we evaluated the utility of robotic US and alternative methods of quantifying PSR staining for PKD research. We compared longitudinal total kidney volume ( TKV ) measurements using US and MR. We additionally compared PSR imaging and quantification using standard brightfield with that by circularly polarized light with hue analysis, and fluorescence imaging analyzed using CT-FIRE software for automatic detection of individual collagen fibers. Results: Increased TKV was detected by US in Pkd1RC/RC vs wild type ( WT ) at timepoints spanning early to established disease. US inter-observer variability was greater but allowed scanning in 2-5 minutes/mouse while MR required 20-30 minutes/mouse. While no change in fibrotic index was detected in this cohort of relatively mild disease using brightfield, polarized light showed fibers skewed thinner in Pkd1RC/RC vs WT. Fluorescence imaging showed a higher density of collagen fibers in Pkd1RC/RC vs WT, and fibers were thinner and curvier with no change in length. Additionally, fiber density was higher in both glomeruli and tubules in Pkd1RC/RC , and glomeruli had a higher fiber density than tubules in Pkd1RC/RC , and trended higher in WT. Conclusions: These studies show robotic ultrasound is a rigorous imaging tool for pre-clinical PKD research. Additionally, they demonstrate the increased sensitivity of polarized and fluorescence analysis of PSR-stained collagen.
What problem does this paper attempt to address?