Comparative study of thulium fiber laser versus holmium:yttrium-aluminum-garnet laser for ureteric stone management with semi-rigid ureteroscopy: A prospective, single-center study

Ankit Gupta,Arvind P Ganpule,Ankush Puri,Abhishek G Singh,Ravindra B Sabnis,Mahesh R Desai
DOI: https://doi.org/10.1016/j.ajur.2023.01.001
Abstract:Objective: To compare the efficacy and safety of thulium fiber laser (TFL) and holmium:yttrium-aluminum-garnet (Ho:YAG) laser for ureteric stone management with semi-rigid ureteroscopy. Methods: In a prospective study from January 2020 to December 2021, we compared 40 patients in each group who underwent semi-rigid ureteroscopic lithotripsy with TFL and that with Ho:YAG laser. Stone volume, stone density, stone fragmentation rates, total lasing time, total operative time, endoscopic vision, retropulsion and stone free rates were analyzed in both groups and compared. Results: Mean stone volume was comparable in the TFL group and the Ho:YAG laser group (282.45 [standard deviation, SD 139.79] mm3 vs. 279.49 [SD 312.52] mm3; p=0.964). Mean stone density was also comparable in the TFL group and the Ho:YAG laser group (1135.30 [SD 317.04] Hounsfield unit vs. 1131.75 [SD 283.03] Hounsfield unit; p=0.959). The mean stone fragmentation rates calculated as stone volume divided by lasing time were 25.85 (SD 10.61) mm3/min and 21.37 (SD 14.13) mm3/min in the TFL group and the Ho:YAG laser group, respectively (p=0.113). The mean total lasing time (10.15 [SD] 4.69 min vs. 11.43 [SD 4.56] min; p=0.222), mean operative time (25.13 [SD 9.51] min vs. 25.54 [SD 10.32] min; p=0.866), and mean total hospital stay (2.62 [SD 0.77] days vs. 2.61 [SD 0.84] days; p=0.893) were comparable in the TFL group and in the Ho:YAG group. The vision was better and retropulsion was less in the TFL group. The stone-free rate at 1 month postoperatively was slightly better in the TFL group (100% vs. 90%; p=0.095). Conclusion: TFL technology was associated with the comparable total surgical time, total lasing time, and stone fragmentation rate with Ho:YAG laser. However, TFL had better endoscopic vision, lesser stone retropulsion, and slightly better stone-free rates.
What problem does this paper attempt to address?