Dynamic PID loop control

L. Pei,A. Klebaner,J. Theilacker,W. Soyars,A. Martinez,R. Bossert,B. DeGraff,C. Darve
DOI: https://doi.org/10.48550/arXiv.1209.4299
2012-09-19
Accelerator Physics
Abstract:The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its Joule-Thompson JT-valve is very important after cryostat cool down to 2.0 K. The 72-cell cryostat liquid level response generally takes a long time delay after regulating its JT-valve; therefore, typical PID control loop should result in some cryostat parameter oscillations. This paper presents a type of PID parameter self-optimal and Time-Delay control method used to reduce cryogenic system parameters' oscillation.
What problem does this paper attempt to address?