Precisely analysis and reconstruction of genu varum and valgum using computer-aided design
DING Huan-wen,ZHANG Di-hui,TU Qiang,WANG Hong,SHEN Jian-jian,YI C,WANG Nan,LIU Hui-liang,YIN Qing-shui,WANG Ying-jun,CHEN Xiao-feng
DOI: https://doi.org/10.3877/cma.j.issn.1674-134X.2012.03.008
2012-01-01
Abstract:Objective To investigate a new way of precise analysis and reconstruction of genua varus and valgum using computer aided design technology, and to evaluate the curative effects. Methods 18 cases of genua varus or genua valgum were treated from September 2005 to September 2010, among which four cases were genua varus, and 14 cases were genua valgum. There were six males and 12 females, aging from 14 to 54 years (average 25.4 years). All patients were examined by lamellar CT scan to harvest two dimensional image of lower limbs. Three dimensional reconstruction of anatomical models was performed by Mimics 10.0 software in computer. 3D models were imported into reverse engineering sofeware Imageware to measure the angles of varus or valgum, femoral angle, femoral condyle-tibial plateau angle, and femorotibial angle. The position and extent of osteotomy can be precisely determined according to the results of computer aided measurement. The surface points cloud data were collected to design individual osteotomy-assisting templates by computer-aided design (CAD) software, and the virtual procedure of the osteotomy and reconstruction of genua varus and valgum were simulated in the reverse engineering software. Four cases of genua varus were performed with high tibial osteotomy + internal fixation, and 14 cases of genua valgum were performed with distal femoral + internal fixation. The hospital for special surgery knee score (HSS) was used to evaluate the preoperative and postoperative functions of the knee joint. Results All patients were followed up for 9-36 months (average 18.7 months); the fracture union time was 8-12 months (average 10.5 months). The load bearing line of lower limb had been completely recovered according to postoperation X-Ray image. The parameter of computer aided measurement had no significant difference (P>0.05) comparing with X-ray measurement. According to X-ray measurement, the angles of genua varus or valgum, femoral angle, femoral condyle-tibial plateau angle, and femorotibial angle had significant difference (P<0.05) comparing preoperative data to postoperative data. The α and β angle and HSS score of traditional method were significant different compared to those of computer aided design method (P<0.05). The average HSS score had increased from (55.4±15.2) in preopertion to (81.8±9.6) in postoperation, and there was significant difference (P<0.05). According to the HSS score at the last follow-up, seven cases were excellent, and four cases were good. No internal fixation device failure, bone nounion, genua varus and valgum recurrence occurred in the follow-up. There was reject reaction of allograft bone in three cases, and it turned out well after symptomatic treatment. Conclusions Precise analysis and reconstruction of genua varus and valgum using computer-aided design will lead orthopedics into an age of digitalization, and provide a much more precise, reliable and better curative effect.