Significance of temperature as a key driver in ZVI PRB applications for PCE degradation

Adrian D Metzgen,Andreas Dahmke,Markus Ebert
DOI: https://doi.org/10.1016/j.jconhyd.2023.104236
Abstract:We report on the potential of elevated groundwater temperatures and zero-valent iron permeable reactive barriers (ZVI PRBs), for example, through a combination with underground thermal energy storage (UTES), to achieve enhanced remediation of chlorinated hydrocarbon (CHC) contaminated groundwater. Building on earlier findings concerning deionized solutions, we created a database for mineralized groundwater based on temperature dependence of tetrachloroethylene (PCE) degradation using two popular ZVIs (i.e., Gotthart-Maier cast iron [GM] and ISPAT sponge iron [IS]) in column experiments at 25 °C-70 °C to establish a temperature-dependent ZVI PRB dimensioning approach. Scenario analysis revealed that a heated ZVI PRB system in a moderate temperature range up to 40 °C showed the greatest efficiency, with potential material savings of ~55% to 75%, compared to 10 °C, considering manageability and longevity. With a 25 °C-70 °C temperature increase, rate coefficients of PCE degradation increased from 0.4 ± 0.0 h-1 to 2.9 ± 2.2 h-1 (GM) and 0.1 ± 0.1 h-1 to 1.8 ± 0.0 h-1 (IS), while TCE rate coefficients increased from 0.6 ± 0.1 h-1 to 5.1 ± 3.9 h-1 at GM. Activation energies for PCE degradation yielded 32 kJ mol-1 (GM) and 56 kJ mol-1 (IS). Temperature-dependent anaerobic iron corrosion was key in regulating mineral precipitation and passivation of the iron surface as well as porosity reduction due to gas production.
What problem does this paper attempt to address?