The ultrasonic degradation of a pharmaceutical formulation including gentamicin sulfate and parabens: Optimization of operational parameters, antibacterial activity assessment, and analysis of resulting by-products
Meriem Sandaoui,Mohamed Amine Aboulfadile,Souraya Sakoui,Reda Derdak,Bouchra El Khalfi,Sanae El Ghachtouli,Mohammed Azzi,Zaina Zaroual
DOI: https://doi.org/10.1016/j.jwpe.2024.104875
IF: 7
2024-01-31
Journal of Water Process Engineering
Abstract:Antibiotics and endocrine disruptors in aquatic environments are typically regarded as potentially hazardous for humans and other living organisms, antibiotics can promote the development of antibiotic-resistant bacteria, meanwhile, endocrine disruptors contribute to the risk of cancer and hormonal imbalances. In this context, the current study aims to investigate the efficacy of a low-frequency (26 kHz) ultrasound horn, in degrading a pharmaceutical solution containing both gentamicin sulfate and parabens. Firstly, the Minimal Inhibitory Concentration (MIC) of the used formulation was determined against four strains of bacteria named: Escherichia coli , Klebsiella pneumoniae , Staphylococcus aureus , and Listeria monocytogenes . Then, the different parameters influencing the degradation were studied and optimized, and the Ultraviolet–visible spectrophotometer (UV) was used to measure the absorbance value of the formulation to assess the degradation rate. The obtained results demonstrated that the concentration 0.160 mg/ml was the selected MIC. Further, the optimized parameters values were found to be: ultrasound power of 90 W, time irradiation of 120 min, temperature of 25 °C ± 2, inherent pH of 4.7, probe immersion depth of 40 mm and 0.15 g/l of sodium sulfate, yielding 78.93 % as degradation extent. The use of 2-propanol as a radical scavenger showed that parabens degradation was probably taking place in the bubble/liquid interface. Furthermore, degradation analyses were performed using different analytical techniques: Ion chromatography (IC) showed the formation of nitrate originated from gentamicin sulfate degradation, High-performance liquid chromatography (HPLC) illustrated the removal of parabens, Mass spectroscopy High-performance liquid chromatography (HPLC/MS) evidenced the formation of some gentamicin sulfate intermediates which were investigated to establish a possible degradation pathway, and at the end, the antibacterial activity was assessed.
engineering, chemical, environmental,water resources