A Highly Energy-Efficient Body-Coupled Transceiver Employing a Power-on-Demand Amplifier

Tao He,Yabin Zheng,Xu Liang,Jiamin Li,Longyang Lin,Wenfeng Zhao,Yongfu Li,Jian Zhao
DOI: https://doi.org/10.34133/cbsystems.0030
2023-08-08
Abstract:Wearable body sensor nodes require massive data transmission under limited energy. However, it suffers from drastically varying channel loss, which limits its energy efficiency in practical scenarios. This paper presents a power-driven body-channel transceiver (TRX), whose power consumption can be adaptively tuned against varying channel loss. An out-band programmable gain amplifier (PGA) is proposed to save power and generate a quasi-linear correlation between PGA gain and power. By using the quasi-linear gain-power relationship, we propose an auto gain/power control technique to realize on-demand power consumption. In addition, a differential balanced transmitter is designed to eliminate base-band harmonics in on-off keying modulation and increase the power delivered by the transmitter (TX). The TX and receiver (RX) of the prototype were integrated into 1 chip and fabricated in a 55-nm complementary metal oxide semiconductor process. During the measurement, 2 chips were configured as TX and RX, respectively. Both the TX and the RX were wearable, powered by lithium batteries, and attached to the subject's hands. The prototype achieved a 5.25-Mbps data rate with 16-pJ/bit energy efficiency at a 1.5-m straight-line ground path distance. Furthermore, the proposed TRX maintained stable communication within a 1.5-m distance, while dynamically reducing power consumption.
What problem does this paper attempt to address?