Deactivation of SARS-CoV-2 with pulsed-xenon ultraviolet light: Implications for environmental COVID-19 control
Sarah E. Simmons,Ricardo Carrion,Kendra J. Alfson,Hilary M. Staples,Chetan Jinadatha,William R. Jarvis,Priya Sampathkumar,Roy F. Chemaly,Fareed Khawaja,Mark Povroznik,Stephanie Jackson,Keith S. Kaye,Robert M. Rodriguez,Mark A. Stibich
DOI: https://doi.org/10.1017/ice.2020.399
2020-08-03
Infection Control and Hospital Epidemiology
Abstract:Abstract Objectives: Prolonged survival of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on environmental surfaces and personal protective equipment may lead to these surfaces transmitting this pathogen to others. We sought to determine the effectiveness of a pulsed-xenon ultraviolet (PX-UV) disinfection system in reducing the load of SARS-CoV-2 on hard surfaces and N95 respirators. Methods: Chamber slides and N95 respirator material were directly inoculated with SARS-CoV-2 and were exposed to different durations of PX-UV. Results: For hard surfaces, disinfection for 1, 2, and 5 minutes resulted in 3.53 log 10 , >4.54 log 10 , and >4.12 log 10 reductions in viral load, respectively. For N95 respirators, disinfection for 5 minutes resulted in >4.79 log 10 reduction in viral load. PX-UV significantly reduced SARS-CoV-2 on hard surfaces and N95 respirators. Conclusion: With the potential to rapidly disinfectant environmental surfaces and N95 respirators, PX-UV devices are a promising technology to reduce environmental and personal protective equipment bioburden and to enhance both healthcare worker and patient safety by reducing the risk of exposure to SARS-CoV-2.
infectious diseases,public, environmental & occupational health