Estimation of the UV susceptibility of aerosolized SARS-CoV-2 to 254 nm irradiation using CFD-based room disinfection simulations

Marc van der Schans,Joan Yu,Adrie de Vries,Genevieve Martin
DOI: https://doi.org/10.1038/s41598-024-63472-3
IF: 4.6
2024-07-11
Scientific Reports
Abstract:The recent COVID-19 pandemic has raised interest in efficient air disinfection solutions. The application of germicidal ultraviolet (GUV) irradiation is an excellent contender to prevent airborne transmission of COVID-19, as well as other existing and future infectious airborne diseases. While GUV has already been proven effective in inactivating SARS-CoV-2, quantitative data on UV susceptibility and dose requirements, needed to predict and optimize the performance of GUV solutions, is still limited. In this study, the UV susceptibility of aerosolized SARS-CoV-2 to 254 nm ultraviolet (UV) irradiation is investigated. This is done by employing 3D computational fluid dynamics based simulations of SARS-CoV-2 inactivation in a test chamber equipped with an upper-room UV-C luminaire and comparing the results to previously published measurements performed in the same test chamber. The UV susceptibility found in this study is (0.6 ± 0.2) m 2 /J, which is equivalent to a D 90 dose between 3 and 6 J/m 2 . These values are in the same range as previous estimations based on other corona viruses and inactivation data reported in literature.
multidisciplinary sciences
What problem does this paper attempt to address?