Bladder perforation by an intrauterine device

A. Schoenfeld,J. Pardo,D. Engelstein,J. Ovadia,C. Servadio
DOI: https://doi.org/10.1002/jcu.1870190310
1991-03-01
Journal of Clinical Ultrasound
Abstract: A case of perforation of the urinary bladder by a Copper 7 IUD inserted in a 32-year old para 5 women 6 months previously is reported. The gynecologist had noted that the insertion was difficult. The patient presented with intermittent abdominal cramping pain and gross hematuria. She had experienced 3 episodes of lower abdominal pain treated with antibiotics and spasmolytic. She has diffuse abdominal tenderness and rebound pain in the pubic region. The only abnormal findings were gross red blood cells in the urine, white blood count of 14,000 and hemoglobin 12.0 g. Real time sonography showed the IUD within the bladder surrounded by hypoechoic echoes found to be blood clots during cystoscopy. A plain abdominal x-ray suggested the IUD was encrusted with calculi. The IUD was removed by cystoscopy. The woman was treated with antibiotics for 10 days and recovered. This is believed to be the 1st published report of an IUD detected by sonography to be in the urinary bladder.
What problem does this paper attempt to address?