Inspiratory muscle loading: a new approach for lowering glucose levels and glucose variability in patients with Type 2 diabetes
A. P. Corrêa,F. R. Figueira,D. Umpierre,K. Casali,B. Schaan
DOI: https://doi.org/10.1111/dme.12798
IF: 3.5
2015-09-01
Diabetic Medicine
Abstract:Glucose variability reflects glycaemic excursions that ultimately contribute to increased levels of protein glycation and oxidative stress [1]; therefore, analysis of glucose variability may be promising as a target for intervention to reduce organ damage in patients with Type 2 diabetes. Physical exercise reduces glycaemia and glucose variability in diabetes [2], but the effects of diaphragm muscle contractions induced by inspiratory loading are still unknown. Accordingly, we aimed to compare glucose levels and glucose variability after aerobic, combined exercise and inspiratory muscle-loading exercise in patients with Type 2 diabetes. Fourteen patients with Type 2 diabetes, treated with metformin participated in a crossover trial from two other studies previously approved by the institutional review board; all participants gave their written informed consent. The participants underwent two conventional exercise protocols (aerobic or combined exercise) in a randomized order. For the aerobic session, participants exercised on a cycle ergometer (Embreex 360, Brusque, Brazil) for 40 min at 70% of peak heart rate. In the combined session, the same aerobic protocol was performed for 20 min, complemented by four resistance exercises (leg press, leg extension, bench press and biceps curl), with three sets of 12 repetitions at 65% of one repetition maximum (1 RM). Six of 14 participants who performed aerobic and combined exercise were also randomly assigned to two sessions of inspiratory muscle-loading exercise [high resistance, 60% of maximum inspiratory mouth pressure (PImax) or low resistance, 2% of PImax]. The inspiratory muscle-loading exercise at 60% of PImax protocol was designed to cause fatigue of the diaphragm at intensities > 80% of maximal oxygen consumption (VO2max) [3]. The participants breathed through a two-way valve (Hans Rudolph, 2600 series; Shawnee, KS, USA) with high resistance of inspiratory muscle at 60% of PImax, connected to a POWERbreathe inspiratory muscle trainer (HaB International, Southam, UK) or to a threshold inspiratory muscle trainer (DHD, Chicago, IL, USA) for low resistance of inspiratory muscle at 2% of PImax. In both protocols, the baseline data were collected during 5 min of spontaneous breathing. Thereafter, distinct inspiratory and expiratory audio tones were used so that participants could maintain a breathing frequency of 15 breaths per min and a duty cycle of 0.7. Inspiratory pressure was continuously recorded and displayed on a computer screen and a 10-point Borg scale was used to assess inspiratory effort at task failure. Inability to maintain breathing was defined as a reduction of PImax to < 80% of the prescription during three consecutive breaths. As the low resistance experiments do not induce task failure (inspiratory muscle-loading exercise, 2% of PImax), measurements were recorded for 5 min. Thus, in the high resistance session at 60% of PImax (inspiratory muscle-loading exercise), the participants performed breath control/3 min; 60% loading/ ~ 5 min and, in the low resistance session at 2% of PImax (inspiratory muscle-loading exercise), they performed breath control/3 min; 2% loading/ 5 min. For all exercise protocols, participants wore a continuous glucose monitoring system. The four experimental sessions took place 7 days apart. Glucose measurements were obtained every 5 min; these profiles were obtained for 30 min before, during and for 30 min after exercise sessions. Glucose standard deviation, glucose variance and glucose coefficient of variation were calculated for each series, before and after sessions. Two-way ANOVA and multiple comparison tests (Student–Newman–Keuls) were performed. Statistical significance was accepted at a P value ≤ 0.05. Participants were aged 56 7 years, had a BMI 30 4 kg.m 2 and HbA1c levels 61 5 mmol/mol (7.9 0.6%), characteristics that were similar between those who performed aerobic, combined and inspiratory muscle loading exercise (n = 6) and those who performed only aerobic and combined exercise (n = 8). Figure 1a shows glucose levels determined by the continuous glucose monitoring system, whichwere reduced after aerobic (25%), combined (11%) and inspiratory muscle-loading exercise at 60% of PImax (24%). Glucose variability evaluated by glucose standard deviation reduced after exercise aerobic and inspiratory muscle-loading exercise at 60% of PImax sessions, but not by combined or inspiratory muscle-loading exercise at 2% of PImax (Fig. 1b). Similar findings were obtained for glucose variability evaluated by glucose variance (Fig. 1c). Glucose coefficient of variation decreased only after inspiratory muscle-loading exercise at 60% of PImax session (Fig. 1d). The low resistance of inspiratory muscle-loading exercise at 2% of PImax did not cause any change in glucose levels. In the present paper, we report for the first time that high resistance of inspiratory muscle exercise at 60% of PImax reduces glucose levels immediately after an acute session, similarly to aerobic and combined sessions. Moreover, aerobic and inspiratory muscle exercise at 60% of PImax promote similar reductions in glucose variability, which were not observed after a single combined session or inspiratory