Application of a 3D-printed eye model for teaching direct ophthalmoscopy to undergraduates

Chan Wu,Mingyue Luo,Yutong Liu,Rongping Dai,Meifen Zhang,Yong Zhong,Youxin Chen
DOI: https://doi.org/10.1007/s00417-021-05538-w
Abstract:Purpose: This study aims to design an eye model that can simulate the fundus for teaching direct ophthalmoscopy and to evaluate its effectiveness. Methods: We first used 3D printing materials to make an eye model and then randomly assigned 92 undergraduates into group A (model-assisted training group) and group B (traditional training group) to test our model. After the same training time, real patients were used to test the students, with 120 s as the examination time limit. We recorded the students' ability to clearly see the optic disk, the time to determine the cup-to-disk ratio, and whether they were correct. Results: Forty-three students in group A (93.48%) successfully saw the fundus, while 21 in group B (45.65%) succeeded. The difference between the two groups was 47.83% (95% confidence interval, 29.59-66.07%, P < 0.0001). The median time to see the fundus was 29s (95% confidence interval 23-45 s) in group A, while an estimated minimum time in group B was 80 s, indicating that group A was significantly faster than group B (P < 0.0001). Conclusions: This 3D-printed eye model significantly improved the students' study interest, study efficiency, and study results and is worthy of being promoted.