Progesterone release profile and follicular development in Nelore cows receiving intravaginal progesterone devices

Lucas Oliveira E Silva,Alessio Valenza,Rodrigo Lemos Olivieri Rodrigues Alves,Mayara Silvestri,Mariana Costa Contini,Jéssica Cristina Lemos Motta,Jéssica Nora Drum,Alexandre Hênryli de Souza,Roberto Sartori
DOI: https://doi.org/10.1016/j.theriogenology.2021.11.005
IF: 2.923
2022-01-15
Theriogenology
Abstract:This study aimed to evaluate the progesterone (P4) release profile provided by four commercially available intravaginal P4 devices, as well as the effect of circulating P4 concentrations exclusively from these devices on the development of the dominant follicle (DF) in Nelore (Bos indicus) cows. Therefore, non-lactating multiparous Nelore cows were enrolled in an experimental design, over three replicates, starting on Day -9 with the insertion of a reused P4 device (2 g - original P4 load) for 7 d, followed by two treatments of cloprostenol sodium (PGF; 0.482 mg), 24 h apart, on Days -3 and -2. Just before device removal, on Day -2, a norgestomet ear implant was inserted and, 2 d later (Day 0), at the time of norgestomet withdrawal, cows were randomly assigned to receive one of the intravaginal devices: Primer (0.5 g); Prociclar (0.75 g); Sincrogest (1 g); or CIDR (1.9 g), and 2 mg of estradiol benzoate (EB) im. Blood samples were collected immediately before P4 device insertion, 12 h later and daily over 15 d (1 d after P4 device removal). Ultrasound examinations were performed on Days 0, 7, 8, 9, 10, 12, and 14 to evaluate ovarian dynamics. Results are presented as mean ± SEM and differences were considered when P ≤ 0.05. Overall, the devices resulted in distinct circulating P4 concentrations over 10 d, varying according to their initial P4 load and P4 impregnated surface area. Primer provided the lowest circulating P4 concentrations over time, whereas, CIDR had the greatest concentration. Sincrogest and Prociclar were similar, producing intermediary circulating P4. There was no effect of treatment on the DF diameter on any specific day, nor on follicular growth rate from Day 7-10. However, the Primer device resulted in a greater mean DF diameter over time. Additionally, greater circulating P4 concentrations, mainly during the first 3 d of device insertion, were associated with smaller DF diameters regardless of the treatment. In conclusion, results from this study provided a better understanding of the P4 profile of intravaginal P4 devices, as well as, their effect on DF development in Bos indicus cows. These data contribute to optimize the use of P4 devices in the reproductive management of beef cattle.
What problem does this paper attempt to address?