Buck Converter with Load Adaptive Losses and 256x sub-mW Load Transient Response Time of 0.8 ms using Synchronous Control

Laxmi Karthikeyan,Bharadwaj Amrutur
DOI: https://doi.org/10.1109/tpel.2024.3364145
IF: 5.967
2024-01-01
IEEE Transactions on Power Electronics
Abstract:The authors propose a pulse-frequency modulation based buck converter that uses synchronous control. The controller clock continuously tracks twice the switching frequency through internal control that employs a primary clock. The system responds to 256x load rise transients within four switching periods using synchronous control to have fine output voltage attributes with a 27 nF-capacitor at output. Zero current switching in 10 ns is achieved using an active diode (AD). Employment of the AD ensures nonoverlap conduction of the switches in the buck converter. The analog AD-controller operates bias-free and the power consumed by it scales with switching frequency. As the average switching frequency is proportional to load, the losses in the main controller and AD-controller scale with load that improves the efficiency at light load. The system fabricated in 180 nm CMOS technology for 1.2 V output voltage, enhances the state-of-the-art transient response rate in synchronous mode (to 2.6657 A in 812.8 s) for limiting the voltage droop to 7 mV. Peak efficiency achieved is 94.8 at 788 W output. Efficiency >80 is obtained for the minimum output power levels of 12.4 W and 1.75 W at primary clocks of 1.25 MHz and 1.2532 MHz, respectively.
engineering, electrical & electronic
What problem does this paper attempt to address?