Comparative Analysis of Two Commercial Automated Systems with Agar Dilution for Oxacillin Susceptibility and Their Association with Genotypes of Invasive Staphylococcus aureus Isolates (2011–2021)
Wei-Yao Wang,Yi-Hsin Chen,Yu-Lin Lee,Chen-Feng Chiu,Shih-Ming Tsao
DOI: https://doi.org/10.2147/idr.s445211
2024-03-20
Infection and Drug Resistance
Abstract:Wei-Yao Wang, 1, 2 Yi-Hsin Chen, 3– 5 Yu-Lin Lee, 1, 2 Chen-Feng Chiu, 6 Shih-Ming Tsao 1, 2 1 School of Medicine, Chung Shan Medical University, Taichung, Taiwan; 2 Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; 3 Department of Nephrology, Taichung Tzu Chi Hospital, Taichung, Taiwan; 4 School of Medicine, Tzu Chi University, Hualien, Taiwan; 5 Department of Artificial Intelligence and Data Science, National Chung Hsing University, Taichung, Taiwan; 6 Department of Internal Medicine, Feng Yuan Hospital, Ministry of Health and Welfare, Taichung, Taiwan Correspondence: Shih-Ming Tsao, Department of Internal Medicine, Chung Shan Medical University Hospital, &num 110, Section 1, Jianguo North Road, Taichung City, 40201, Taiwan, Tel +886 4 24739595 ext.34718, Fax +886-4-23248172, Email Background: Determining oxacillin susceptibility using reference methods and automated systems is crucial for treating invasive infections caused by Staphylococcus aureus . This study compares the oxacillin susceptibility results from the two automated systems with agar dilution and correlates them with genotypes of invasive S. aureus . Methods: Non-duplicate S. aureus invasive isolates were collected over an 11-year period. The oxacillin susceptibility was determined with Phoenix 100 (Jan 2011 to Aug 2018) or Vitek 2 (Sep 2018 to Dec 2021), and susceptibility for oxacillin and cefoxitin was determined with agar dilution. Methicillin-resistant S. aureus (MRSA) was confirmed with mecA existence, and the genotype was determined using SCC mec . The association between genotype and antibiotic susceptibility using two automated systems and agar dilution was evaluated. Results: A total of 842 invasive S. aureus , including 443 mecA + MRSA and 399 mecA - MSSA, were collected. The susceptibility rates of oxacillin determined by two automated systems and agar dilution were 68.8% (76.8% for Phoenix 100 and 57.6% for Vitek 2) and 54.0%, respectively. When compared with the oxacillin susceptibility using agar dilution, the categorical agreement for Phoenix 100 and Vitek 2 were 0.46% and 0.88%, respectively ( p < 0.001). One hundred and forty-three isolates were misinterpreted as oxacillin-susceptible S. aureus (OSSA) using automated systems while comparing with agar dilution, among which molecularly community-associated MRSA (CA-MRSA) outnumbered healthcare-associated MRSA (HA-MRSA) (99 vs 34, p < 0.001). There were 70 mecA + OSSA (OS-MRSA) using agar dilution, among which 42 harbored SCC mec types were predominantly categorized as CA-MRSA (38, p < 0.001). Conclusion: The categorical agreement of Vitek 2 in determining oxacillin susceptibility and predicting mecA existence is comparable with agar dilution, whereas Phoenix 100 is not. Most of those ORSA determined by agar dilution but misinterpreted as OSSA by automated systems and OS-MRSA are categorized as CA-MRSA. Keywords: oxacillin susceptibility, automated systems, agar dilution, SCC mec , CA-MRSA Staphylococcus aureus , encompassing methicillin-susceptible (MSSA) and methicillin-resistant S. aureus (MRSA), is the predominant pathogen causing various invasive infections in both community and healthcare settings 1,2 The crude mortality rates of invasive infections by MRSA range from 10.2% for bacteremia to 55.6% for septic shock. 2 MRSA has not only replaced MSSA, but its hospitalization rates have also surpassed those by MSSA. 3 Determining methicillin resistance, mediated by penicillin-binding protein 2a (PBP2a), is essential for appropriate antibiotic treatment in clinical practice. 4 Automated systems have been implemented for accurate species identification and rapid determination of antibiotic susceptibility, 5 but discrepancies between automated systems and the reference antibiotic susceptibility test (AST) have also been reported. 6 The goals of this study are to compare the oxacillin susceptibility results between the two commercial automated systems and the reference AST (categorical agreement, CA) and to investigate the association between the discrepancy of AST results and the genotypes of MRSA. Invasive Staphylococcus aureus isolates cultivated from sterile sites were identified using standard microbiologic methods and two commercial automated identification and antibiotic susceptibility test systems. These two systems, Phoenix 100 (BD Diagnostic Systems, Sparks, Md, USA, f -Abstract Truncated-
pharmacology & pharmacy,infectious diseases