Case 5--2000. Confusion of aortic valve and parts of an aortic root prosthesis during intraoperative transesophageal echocardiography.
J. Lutz,J. Piotrowski,F. Splittgerber,M. Katz,J. Peters
DOI: https://doi.org/10.1053/JCAN.2000.9499
IF: 2.894
2000-10-01
Journal of Cardiothoracic and Vascular Anesthesia
Abstract:An 81-year-old woman with aortic valve stenosis (31), aortic valve insufficiency (11), and coronary artery disease was scheduled for elective aortic valve replacement and coronary bypass surgery. The patient suffered from syncopal episodes and dyspnea at rest. Comorbidities were slight renal insufficiency, diabetes mellitus type IIb, and hyperlipoproteinemia. The patient received oral digitoxin, furosemide, simvastatin, glibenclamide, bisoprolol, and ramipril. Preoperative transesophageal echocardiography (TEE) and transthoracic echocardiography had shown a severely calcified aortic valve (area, 0.7 cm2), left ventricular hypertrophy (wall thickness, 16 mm), and a transvalvular maximum systolic gradient of 88 mmHg (mean, 54 mmHg). Ejection fraction was 50%. Cardiac catheterization had revealed a 70% stenosis of the left anterior descending coronary artery (LAD). Intraoperatively a severely calcified aortic valve and ascending aorta and a small aortic root (size, 21 mm obturator) were found. A size 21 aortic root prosthesis (Freestyle, Medtronic, Irvine, CA) carrying a porcine aortic valve was implanted using the freehand subcoronary technique, and the left internal mammary artery was anastomosed to the LAD. On weaning from cardiopulmonary bypass, the electrocardiogram (ECG) suggested severe posterior and inferior wall ischemia, and the patient was hemodynamically unstable despite inotropic support (0.05 to 0.1 μg/kg/min of epinephrine). Cardiopulmonary bypass was reinstituted, and a saphenous vein graft was anastomosed to the right coronary artery. A second attempt to wean from bypass succeeded with an epinephrine infusion (0.1 μg/kg/min), yielding a cardiac index of 2.3 L/min/m2. A systolic thrill was felt over the ascending aorta, however, and invasive pressure measurements revealed a maximum systolic pressure gradient of 50 mmHg between the left ventricle (transseptal measurement) and the radial artery. With respect to the patient’s age, the long duration of cardiopulmonary bypass, and the initial problems with weaning from bypass, it was decided to transfer the patient to the intensive care unit without inspection of the implanted prosthesis. Hemodynamic instability worsened despite increased epinephrine dosages. A TEE examination in the intensive care unit at first revealed no apparent gross abnormalities of the prosthesis. A small jet into the ascending aorta originating from the prosthesis could be seen in the aortic long-axis view, however. At that time, the estimated maximum pressure gradient across the prothesis was 60 mmHg (measured from a deep transgastric long-axis view of the aortic valve). The patient was brought back to the operating room, where a more detailed TEE examination was performed during preparation for cardiopulmonary bypass. An apparently perfect opening and closure of the artificial aortic valve was visualized (Fig 1). It was noticed that the valve appeared somewhat thickened, however, and during further withdrawal of the TEE probe, a second Mercedes star–shaped structure could be seen (Fig 2).After meticulous inspection of the valve in multiple planes, it was concluded that the structure seen in Fig 2 was a portion of the Dacron ring of the prosthesis collapsing into the aortic lumen with every left ventricular contraction. Direct inspection of the prosthesis confirmed this finding. Although the valve leaflets of the prosthesis were intact, infolding protrusions of parts of the Dacron suture ring below the leaflets were noticed. The prosthesis with the folded Dacron ring is shown in Figs 3, 4, and 5. Apparently, this inward movement of the Dacron ring had caused severe stenosis as observed by TEE. The prosthesis was removed, and an aortic root replacement with a size 23 prosthesis (Freestyle) was performed. No leaks, signs of stenosis, or important valve insufficiency were seen after weaning from bypass. Fifteen minutes after termination of bypass, however, the patient died from left ventricular failure refractory to therapy.