Poor Circulation, Early Brain Injury, and the Potential Role of Red Cell Transfusion in Premature Newborns

C. Andersen,C. Collins
DOI: https://doi.org/10.1542/peds.2005-3197
2006-04-01
PEDIATRICS
Abstract:STAGNANT HYPOXIA There are a number of different forms of hypoxia, namely, stagnant (inadequate flow), anemic (inadequate hemoglobin concentration), hypoxic (inadequate inspired oxygen), and histotoxic hypoxia. Barcroft first described stagnant hypoxia in 19204 with the sentence “[the] blood is normal but is supplied to the tissues in insufficient quantities.” The principal determinants of systemic oxygen transport are CO, hemoglobin concentration, and hemoglobin saturation.5 Final tissue oxygen extraction depends on the oxygen diffusion gradient, the diffusion distance between the capillary and the cell, and cellular uptake mechanisms. The degree of oxygen extraction varies between tissues but never reaches 100%. When oxygen delivery decreases to a critical level, oxygen extraction increases but reaches a maximum. Oxygen consumption is subsequently limited by the supply. An oxygen debt develops, and anaerobic metabolism results in lactic acidemia.6 Mixed venous oxygen saturation is the saturation of blood in the pulmonary artery. It is an indicator of whole-body oxygen equilibrium because it represents the residual oxygen in systemic blood after circulation through the tissues. It has been used as a predictor of mortality in infants after cardiac surgery.7,8 It has been calculated9 but not directly measured in premature newborns. Right atrial saturation has been used for newborns10,11 but is confounded by incomplete atrial mixing. Animal models demonstrate that critical mixed venous oxygen saturation, when oxygen consumption is limited by supply, is highest in stagnant hypoxia,12–15 which we believe highlights the importance of CO in oxygen delivery. Fetal tolerance of low saturation states is primarily the result of high placental blood flow.16 Blood pressure is often used as a clinical measure of circulation in newborns; however, it is only weakly correlated with CO (r 0.38).17 Measurement of ventricular output is significantly complicated by the presence of ductal and atrial shunts, which are almost universal in the preterm population. Superior vena cava (SVC) flow is blood flow returning from the brain and upper body and is unaffected by cardiac shunts. Measurement of SVC flow has been validated as a noninvasive measurement of CO in preterm infants, and a “normal range” has been defined.1
What problem does this paper attempt to address?