Experimental evaluation of the thermal, lighting, and energy performances of a mechanically ventilated double-skin façade with Venetian blinds and a light shelf

Chenyuan Zheng,Chen Chen,Xiaoqiang Hong,Weiyou Zhang,Ruiyang Yang,Feng Shi
DOI: https://doi.org/10.1016/j.enbuild.2024.113947
IF: 7.201
2024-01-28
Energy and Buildings
Abstract:Double-skin façades (DSFs) are increasingly being utilized as high-performance building envelope structures. Nevertheless, their shortcomings regarding overheating during the summer are apparent. To improve the energy efficiency and indoor environment, a mechanically ventilated DSF with Venetian blinds (VBs) and a light shelf system (multisectional DSF system) was proposed. A multisectional DSF system and a single-glazed window with VBs were compared. The benefits of the multisectional DSF system over a single-glazed window with VBs in Xiamen were investigated in non-air-conditioned environments in summer and winter and air-conditioned environments in summer. The results indicated that using a multisectional DSF system effectively reduced indoor temperatures by up to 6.9 °C under non-air-conditioned environment in summer, improving Useful Daylight Illuminance (UDI 300–1000 lx ) by 31 % and achieving an energy saving rate of 49.76 % compared to that using VBs. In an air-conditioned environment in summer, an energy-saving rate of 42.96 % was achieved. In a non-air-conditioned environment in winter, using a multisectional DSF system reduced indoor temperatures by up to 7.4 °C in the middle of the day and 1 °C at night compared with that using VBs, improving the UDI 300–1000 lx by 4 % and achieving an energy saving rate of 84.16 %.
energy & fuels,construction & building technology,engineering, civil
What problem does this paper attempt to address?