Optimization of Au Electrode Parameters for Pathogen Detection in Aquaculture

Marcin Paweł Prządka,Damian Wojcieszak,Katarzyna Pala
DOI: https://doi.org/10.1109/jsen.2024.3350388
IF: 4.3
2024-03-02
IEEE Sensors Journal
Abstract:This study investigates the impact of surface roughness and wettability of gold (Au) electrodes on the formation of bioreceptor layers and impedance response for pathogen detection in aquaculture. Using a range of electrodes with varying thicknesses, we observed that increased roughness positively influences bioreceptor layer formation. In addition, enhanced wettability, indicated by reduced wetting angles, was observed across all electrode groups following bioreceptor layer formation. Electrochemical impedance analysis revealed that Au electrodes with lower roughness exhibited more desirable Nyquist plot shapes. A comprehensive analysis of roughness and wettability measurements led to the development of an innovative figure-of-merit (FoM) criterion for assessing biosensor quality in aquaculture during production. In addition to the primary FoM criterion, supplementary criteria were introduced, including wettability criteria (C1 and C2) and a roughness criterion (C3). Our findings demonstrate that the practical application of this innovative multicriteria approach provides a sophisticated tool for monitoring the biosensor preparation process, particularly in the context of aquaculture applications.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?