Precision assessment of bowel motion quantification using 3D cine-MRI for radiotherapy

Danique L J Barten,Zdenko van Kesteren,Janna J Laan,Mathijs G Dassen,G Henrike Westerveld,Bradley R Pieters,Catharina S de Jonge,Jaap Stoker,Arjan Bel
DOI: https://doi.org/10.1088/1361-6560/ad1f89
IF: 3.5
2024-01-19
Physics in Medicine and Biology
Abstract:Objective: The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time. Approach: We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10-minute pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 seconds per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 minutes, respectively. Main results: For the full 10-minute scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5-minute scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 minutes achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively. Significance: Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5-minute scan time.
engineering, biomedical,radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to evaluate the accuracy of quantifying intestinal movement using 3D cine - MRI technology and estimate the shortest MRI acquisition time required to accurately quantify intestinal movement. Specifically, the study aims to: 1. **Evaluate the accuracy**: Evaluate the accuracy of intestinal movement quantification indicators by analyzing subsets of images within different time frames. 2. **Determine the shortest acquisition time**: Find the shortest MRI acquisition time that can achieve accurate intestinal movement quantification without sacrificing measurement accuracy. ### Background In pelvic and abdominal radiotherapy, the intestine is an important organ at risk and is vulnerable to radiation toxicity. Identifying high - and low - movement areas by MRI during radiotherapy can help understand the mechanism of intestinal toxicity. However, the long acquisition time of conventional MRI limits its clinical application. ### Methods The study included 22 gynecological cancer patients who received radical radiotherapy. Each patient underwent a 10 - minute 3D cine - MRI scan before treatment. Each scan contained 160 dynamic images, and the acquisition time for each volume was 3.7 seconds. 159 deformation vector fields (DVFs) were generated through the deformation registration of consecutive images. Two movement indicators were defined: - **The 50th percentile vector length (VL50)**: Used to measure the median intestinal movement. - **The 95th percentile vector length (VL95)**: Used to quantify the high - movement intestinal areas. The accuracy of these indicators was evaluated by calculating their variation (interquartile range) within different time frames. The time frames corresponded to 40, 80, and 120 consecutive images, with corresponding acquisition times of 2.5, 5.0, and 7.5 minutes, respectively. ### Main results - For the complete 10 - minute scan, the minimum movement ranges of the VL50 movement indicator for all patients were 0.6 - 3.5 mm, and the minimum movement ranges of the VL95 movement indicator were 2.3 - 9.0 mm. - For a 7.5 - minute scan time, the proportions of M50% variation of VL50 and VL95 less than 0.5 mm were 100% and 95%, respectively. - Scan times of 5.0 minutes and 2.5 minutes achieved variations within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively. ### Significance The study results show that using a 7.5 - minute 3D cine - MRI scan can quantify the movement of the intestinal loop with an accuracy of 0.5 mm or less at a confidence level of 95% - 100%. This provides important support for optimizing radiotherapy plans and reducing radiation - induced intestinal toxicity.