A Novel Microwave Sensor Based on Modified Rat-Race Coupler for Extracting Real Permittivity and Concentration of Binary Aqueous Solution

Wen-Jing Wu,Wen-Sheng Zhao,Wensong Wang
DOI: https://doi.org/10.1109/jsen.2024.3380579
IF: 4.3
2024-01-01
IEEE Sensors Journal
Abstract:A novel microwave sensor based on modified rat-race coupler for extracting complex permittivity of binary aqueous solution is proposed in this manuscript. The proposed microwave sensing system consists of the modified rat-race coupler, Gain/phase RF detector, and voltage-controlled oscillator (VCO). The modified rat-race coupler is constituted by three cascaded rat-race couplers, each rat-race coupler is developed from a traditional rat-race coupler, and a 50 Ω characteristic impedance transmission line port of traditional coupler is replaced by a muti-stepped impedance transmission line (MSITL), which is used as sensing area. For a rat-race coupler, its sensitivity is determined by the added MSITL, thus the change rate between phase of reflection coefficient and concentration/real permittivity of sample for MSITL should realize the maximum value. Mathematical analysis provides a detailed explanation for what values of characteristic impedance and electrical length of each discontinuous segment of MSITL should be taken to achieve the maximum sensitivity. The relationship between concentration/real permittivity and phase of reflection coefficient can be obtained by the passive sensor, i.e., modified rat-race coupler, while the expensive vector analyzer network (VNA) is essential in measurement. In measurement, the VCO generates the RF signal source at 2.5 GHz for the microwave sensing system. And, the gain/phase detector chip AD8302 is adopted to acquire the relation between permittivity and output DC voltage, thus the output DC voltage can be used to predict the unknown concentration/real permittivity of sample and it can get rid of the use of VNA. For the modified rat-race coupler cascaded by three rat-race couplers, the magnitude of b1/b′′4 (b1 and b′′4 are the output powers for the ports of modified rat-race coupler) is larger than the one of single rat-race coupler, and the larger magnitude of b1/b′′4 denotes the larger output DC voltage for Vmag. In measurement, the modified rat-race coupler has the maximum sensitivity of about 1.37°/ε′r. And the average sensitivity for the microwave sensing system with third-order rat-race coupler combined is about 2.14 mV/ε′r, which is 1.93 ~ 3.28 times higher than single- and second-order rat-race coupler-based ones. All in all, the proposed microwave sensing system is an economical electronic device in the field of microfluidic detection.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a cost - effective microwave sensor for extracting the complex permittivity of binary aqueous solutions. Specifically, the main objectives of the research include: 1. **Improve Sensitivity**: By optimizing the parameters of the Multi - Stepped Impedance Transmission Line (MSITL), maximize the rate of change between the reflection coefficient phase and the sample concentration or real - part permittivity, thereby improving the sensitivity of the sensor. 2. **Reduce Cost and Complexity**: Traditional microwave sensors usually rely on expensive Vector Network Analyzers (VNA) for measurement. The sensor system proposed in this paper can replace the VNA by introducing a Voltage - Controlled Oscillator (VCO) and a Gain/Phase Detector, reducing the cost of the system and simplifying its structure. 3. **Achieve Portability and Compactness**: By introducing active Radio - Frequency (RF) circuits, the detection system becomes more compact and portable, solving the problems of large volume and inconvenient movement of traditional sensors. 4. **Expand the Application Range**: This sensor has potential application value in the field of microfluidic detection. It can quickly and accurately measure the dielectric properties of liquid samples and is suitable for multiple fields such as materials science, biomedicine, and the chemical industry. ### System Composition This microwave sensing system mainly consists of the following parts: - **Improved Rat - Race Coupler**: Composed of three cascaded Rat - Race couplers, one of whose ports is connected to a Multi - Stepped Impedance Transmission Line (MSITL) as the sensing area. - **Voltage - Controlled Oscillator (VCO)**: Generates a 2.5 - GHz radio - frequency signal source. - **Gain/Phase Detector (AD8302)**: Used to obtain the relationship between the permittivity and the output direct - current voltage, thereby predicting the concentration or real - part permittivity of an unknown sample. ### Key Innovation Points - **Multi - Stepped Impedance Transmission Line (MSITL) Optimization**: Determine the optimal values of the characteristic impedance and electrical length of the MSITL through mathematical analysis to achieve maximum sensitivity. - **Cascaded Coupler Design**: Three cascaded Rat - Race couplers increase the amplitude of the output direct - current voltage, thereby improving the overall sensitivity of the system. - **No Need for VNA**: By introducing the VCO and the Gain/Phase Detector, the need for an expensive VNA is eliminated, reducing the cost and simplifying the system. ### Summary This research proposes a microwave sensor based on an improved Rat - Race coupler. By optimizing the MSITL parameters and the cascaded coupler design, a high - sensitivity, low - cost, and portable permittivity measurement system is achieved. This innovation provides new solutions for fields such as microfluidic detection.