RapidpulseTM cyclic aspiration system for acute ischemic stroke due to large vessel occlusions
Arsida Bajrami,Serdar Geyik,Ozgur Ertugrul,Eren Erdem,Jose I Gallego Leon,Giorgio Barbieri,Carlos Dominguez Rodriguez,Jose Carlos Rayón-Aledo,Antonio I Sagredo Barra,Fernando S Sanchez Blanco,Carmen Serna Candel,Francisco Jose Montalverne,Lidemarcks I Andrade,Diego Bandeira,Jose Bezerra,Hellen Carm,Henrique Coelho Silva,Alessandra Braga Cruz Guedes de Morais,Adson Freitas de Lucena,Fabricio O Lima,George Mendes,Felipe A Rocha,Karlis Kupcs,Helmuts Kidikas,Janis Vetra,Gyula Gal,Anabel Diaz,Raul G Nogueira
DOI: https://doi.org/10.1177/15910199241239094
IF: 1.7
2024-03-24
Interventional Neuroradiology
Abstract:Interventional Neuroradiology, Ahead of Print. BackgroundThe best strategy to achieve optimal reperfusion outcomes during mechanical thrombectomy remains to be defined. The RapidPulseTM Cyclic Aspiration System is a novel technology, delivering high-frequency pulsed vacuum forces to increase the efficiency of aspiration thrombectomy.MethodsProspective, multicenter, open-label, core lab-adjudicated, two-arm study comparing safety and efficacy of a feasibility version of the RapidPulseTM system compared with contemporary controls. Primary endpoint was the rate of mTICI ≥ 2c after first-pass effect (FPE). Additional efficacy endpoints were the rates of mTICI [math] 2b after first pass (modified FPE (mFPE)), last pass with study device defined as frontline technical success, and after all passes including rescue therapy. The primary safety endpoints included symptomatic ICH (sICH) within 24 h post-procedure.ResultsBetween February 2022 to December 2022, 80 subjects were consented and enrolled in the study (n = 40 treatment arm, n = 40 control arm). In the intent to treat (ITT) population, mean age was 67.8 ± 11.5 years; 19 (47.5%) were male. Median NIHSS score was 16 (IQR: 13–22). Median ASPECTS score was 9 (IQR: 8–10). The rate of mTICI ≥ 2c after first pass was 53.9% in ITT population (60.0% in per-protocol population) versus 38.5% in the corresponding control population. Functional independence (mRS 0-2) at 90 days was achieved in 61.1% (22/36) in the RapidPulseTM arm and 52.8% (19/36) in the control arm. In the RapidPulseTM arm, no sICH within 24 h and no device-related morbidity or mortality occurred.ConclusionPreliminary data suggests RapidPulseTM Aspiration System is highly effective and safe for recanalization of large vessel occlusions.
radiology, nuclear medicine & medical imaging,clinical neurology