Dispersive liquid-liquid microextraction as a preconcentration alternative to increase ETAAS sensitivity in the analysis of molybdenum in bovine meat and pasture samples

Ignacio Machado,Florencia Tissot
DOI: https://doi.org/10.1016/j.talanta.2020.120783
IF: 6.1
2020-05-15
Talanta
Abstract:A new procedure combining dispersive liquid-liquid microextraction and electrothermal atomic absorption spectrometry was proposed for the determination of molybdenum in plants and animal tissue. The optimized conditions for the microextraction procedure were: 150 μL of 0.3 mol L-1 potassium ethyl xanthate (pH 1.4) and 1000 μL of acetonitrile and 50 μL of carbon tetrachloride as dispersive and extractant solvent, respectively. A limit of detection of 0.03 μg kg-1 and a limit of quantification of 0.11 μg kg-1, as well as an enrichment factor of 200, were achieved employing this procedure. Standard reference materials were used for trueness and precision evaluation. No significant differences were found at the 95% confidence level between certified and obtained values, and the precision expressed as repeatability (sr %) was 4.1% for animal tissue and 4.7% for plant material. The method was successfully applied for the determination of Mo in bovine meat and pasture samples from different livestock establishments.
What problem does this paper attempt to address?