Endwall film-cooling in a cascade with filleted vane, upstream discrete slots, and holes

Adeola S. Shote,Barbara B. Huyssen,Gazi I. Mahmood
DOI: https://doi.org/10.1080/08916152.2024.2424820
2024-11-13
Experimental Heat Transfer
Abstract:In vane cascades, large filleted vanes influence aerodynamics, while upstream endwall film-cooling arrangement impacts aero-thermal performance. This study explores experimental investigations on endwall flows and film-cooling effectiveness in a filleted vane cascade using discrete slots and holes. Two fillet profiles are examined covering the leading-edge area to either the throat or 62% of the axial chord. Film-cooling employs two slots and two rows of holes in the leading-edge region with inlet blowing ratios ranging from 1.0 to 2.8. Results show variations in total pressure loss and Nusselt number between filleted and un-filleted vanes, highlighting optimal film-cooling effectiveness with the smaller fillet profiles.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?