Removal of Polymerase Chain Reaction Inhibitors by Electromembrane Extraction

Cong Liu,Daixin Huang,Liuqian Yang,Shifan Wu,Xiantao Shen,Stig Pedersen-Bjergaard,Chuixiu Huang
DOI: https://doi.org/10.1021/acs.analchem.1c01689
IF: 7.4
2021-08-12
Analytical Chemistry
Abstract:Polymerase chain reaction (PCR) technology has become the cornerstone of DNA analysis. However, special samples (e.g., forensic samples, soil, food, and mineral medicine) may contain powerful PCR inhibitors. High levels of inhibitors can hardly be sufficiently removed by conventional DNA extraction approaches and may result in the complete failure of PCR. In this work, the removal of PCR inhibitors by electromembrane extraction (EME) was investigated for the first time. To demonstrate the universality of the approach, EME formats with and without supported membranes (termed parallel-EME and μ-EME, respectively) were employed, and both anionic [humic acid (HA)] and cationic (Ca2+) PCR inhibitors were used as models. During EME, charged inhibitors in the sample migrate into the liquid membrane in the presence of an electric field and might further leech into the waste solution, while PCR analytes remain in the sample. After EME, the clearance values for HA at 0.2 and 2.5 mg mL–1 were 94 and 85%, respectively, and that for Ca2+ (275 mM) was 63%. Forensic PCR–short tandem repeat (PCR–STR) genotyping showed that EME significantly reduced the interference by HA in PCR–STR analysis and displayed a higher HA purge capability compared to existing methods. Furthermore, by combining EME with liquid–liquid extraction or solid-phase extraction, satisfactory STR profiles were obtained from HA-rich blood samples. In addition, false-negative reports of bacterial detection in mineral medicine and shrimps were avoided after the removal of Ca2+ by μ-EME. Our research demonstrates the great potential of EME for the purification of DNA samples containing high-level PCR inhibitors and opens up a new application direction for EME.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.1c01689.Chemicals and samples, chemical structure of HA, growth conditions of S. aureus, setup of the 96-well Pa-EME system, setup of the μ-EME unit, measurement of HA and Ca2+ concentrations, sample purification by existing methods, qPCR procedure, details of the AGCU EX20 STR kit, inhibitory effect of HA on qPCR, visualization of EME results at 0 and 4 V, measurement of DNA concentration by qPCR, comparison of purification performance of the three methods (EME, LLE, and SPE) by STR genotyping, STR profiles of silica-column-based SPE combined with EME for HA-rich blood purification, qPCR results of magnetic bead-based SPE combined with EME for HA-rich blood purification, inhibitory effect of Ca2+ on qPCR, and qPCR results of μ-EME of aqueous extract of S. aureus contaminated shrimp powder (PDF)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?