Array capacitive proximity sensors-based liquid level measurement under various cup postures

Haipeng Wang,Shuai Zhang
DOI: https://doi.org/10.1016/j.sna.2024.115673
IF: 4.291
2024-07-14
Sensors and Actuators A Physical
Abstract:An array capacitive proximity sensors-based liquid level measurement under various cup postures is proposed in this study. Firstly, a total of 6 rectangular electrodes are arranged around the cup for parasitic capacitance measurement. The relationship between parasitic capacitance and liquid level is calibrated by preliminary experiments. Then, the liquid level under different parasitic capacitance can be obtained. At the same time, an IMU is fixed on the claw. By fusing the parasitic capacitance measured on multiple electrodes with the IMU data, the liquid level under different cup postures is calculated. Experiments confirm the effectiveness of the proposed method. Specifically, The measurement accuracy can be guaranteed within 91 % in the upright state of the cup. An accuracy of 85 % can be guaranteed when the cup inclined angle reaches 30° .
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?