Capacitive and Non-Contact Liquid Level Detection Sensor Based on Interdigitated Electrodes with Flexible Substrate

Yong Ren,Bin Luo,Xueyu Feng,Zihao Feng,Yanyi Song,Fang Yan
DOI: https://doi.org/10.3390/electronics13112228
IF: 2.9
2024-06-08
Electronics
Abstract:Achieving accurate and high-sensitivity liquid level detection in medical instruments has always been a knotty task. In this paper, a high-precision, non-contact, flexible capacitive liquid level sensor is proposed, aiming to apply capacitive sensors in test tube liquid level measurement and improving the sensitivity of real-time liquid level sensors. The simulation study is conducted using ANSYS Maxwell and demonstrates the correlation between test tube thickness and sensitivity. A geometric model of the test container and sensing electrodes is established to optimize the design strategy for the physical dimensions of the sensor's interdigitated (IDT) electrodes based on a flexible printed circuit (FPC). The hardware and software designs are completed based on the FDC2214 capacitive-to-digital converter to collect the capacitance variation data of the sensing electrodes accurately. To assess the system's performance, an experimental platform for a liquid level sensor system has been constructed, facilitating the measurement, communication, processing, and visualization of liquid levels. The performance results demonstrate that the system is capable of accurately measuring the effective liquid level range within a standard 5 mL test tube with a resolution of up to 1 mm, as well as a sensitivity of 78.68 fF/mm, verifying the simulation results and exhibiting excellent linearity.
engineering, electrical & electronic,computer science, information systems,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve high - precision, non - contact liquid level detection in medical instruments. Specifically, the paper proposes a high - precision, non - contact capacitive liquid - level sensor based on interdigitated electrodes (IDT) on a flexible substrate, aiming to improve the sensitivity of real - time liquid - level sensors and apply it to the measurement of liquid levels in test tubes. ### Background and Problem Description - **Importance of Liquid - Level Detection**: In medical instruments, liquid - level detection is a key component of in - vitro diagnostic (IVD) instruments, directly affecting the accuracy and safety of automated detection. - **Limitations of Existing Technologies**: - **Contact Methods**: Such as the resistance method, capacitive probe method, capacitive immersion method, and optical fiber method, have the advantages of simple structure and low cost, but also face problems such as high power consumption, inability to detect non - conductive liquids, and easy contamination or oxidation. - **Non - contact Methods**: Such as the ultrasonic method, microwave method, and acoustic resonance method, although they avoid direct contact with the liquid, the equipment is relatively expensive and may be sensitive to certain chemical reactions, resulting in container breakage or damage to the components in the liquid. ### Solutions in the Paper - **Proposed Technology**: A non - contact capacitive liquid - level sensor based on interdigitated electrodes (IDT) on a flexible substrate. - **Technical Advantages**: - **High Sensitivity**: By optimizing the electrode structure and materials, a sensitivity of up to 78.68 fF/mm has been achieved. - **Non - contact**: Avoids liquid contamination and oxidation problems. - **Flexibility**: Using a flexible printed circuit (FPC), it can better conform to the test - tube wall and improve the detection accuracy. - **Low Cost**: It has a simple structure, is easy to manufacture, and is low - cost. ### Experimental Verification - **Simulation Study**: ANSYS Maxwell was used for modeling and simulation to study the relationship between test - tube thickness and sensitivity. - **Experimental Platform**: An experimental platform for a liquid - level sensor system was constructed to measure, communicate, process, and visualize the liquid level. - **Performance Evaluation**: The experimental results show that the system can accurately measure the effective liquid - level range with a resolution of 1 mm in a standard 5 - mL test tube, verifying the simulation results and showing good linearity. ### Formula Analysis - **Capacitance Calculation Formula**: \[ C=\frac{\epsilon\cdot A}{d}=\int\epsilon\cdot E\cdot d\Omega=\int\epsilon\cdot(-\nabla\phi)\cdot d\Omega \] where \( \epsilon \) is the dielectric constant, \( A \) is the electrode area, \( d \) is the electrode spacing, \( E \) is the electric field strength, and \( \phi \) is the potential distribution function. - **Sensitivity Definition**: \[ S = \frac{\Delta C}{\Delta h} \] where \( \Delta C \) is the capacitance change and \( \Delta h \) is the liquid - height change. ### Conclusion By designing and optimizing a non - contact capacitive liquid - level sensor based on interdigitated electrodes on a flexible substrate, the paper has successfully solved the deficiencies of existing technologies in terms of sensitivity, cost, and reliability, providing a new solution for liquid - level detection in medical instruments.