Research on depth measurement calibration of light field camera based on Gaussian fitting

Miao Yang
DOI: https://doi.org/10.1038/s41598-024-59479-5
IF: 4.6
2024-04-17
Scientific Reports
Abstract:Optical field imaging technology does not require a complicated optical path layout and thus reduces hardware costs. Given that only one single exposure of a single camera can obtain three-dimensional information, this paper proposes an improved calibration method for depth measurement based on the theoretical model of optical field imaging. Specifically, the calibration time can be reduced since the Gaussian fitting can reduce the number of refocused images used to obtain the optimal refocusing coefficient calibration. Moreover, the proposed method achieves the same effect as the multiple refocusing calibration strategy but requires less image processing time during calibration. At the same time, this method's depth resolution is analyzed in detail.
multidisciplinary sciences
What problem does this paper attempt to address?
### Problems Addressed by the Paper This paper primarily addresses the issue of depth measurement calibration based on light field imaging technology. Specifically, the authors propose an improved depth measurement calibration method, which is based on the light field imaging theoretical model and reduces the number of refocused images through Gaussian fitting to shorten the calibration time. This method can achieve the same effect as the multiple refocusing calibration strategy but requires less image processing time during calibration. Additionally, the paper provides a detailed analysis of the depth resolution of the proposed method. ### Main Contributions 1. **Reduced Calibration Time**: The number of refocused images is reduced through Gaussian fitting, thereby shortening the calibration time. 2. **Increased Efficiency**: Significantly reduces image processing time while maintaining accuracy. 3. **Detailed Analysis of Depth Resolution**: Provides a detailed theoretical analysis of the proposed depth measurement method, exploring the optimal refocusing coefficients at different depth positions. ### Experimental Validation The authors validated the effectiveness of the proposed method through experiments, including: - Conducting depth calibration experiments using point light sources. - Analyzing the impact of different numbers of refocused images on the depth calibration range, suggesting selecting approximately 10 refocused images per depth position to determine the optimal refocusing coefficient. ### Conclusion This paper demonstrates how to achieve refocused image rendering by combining ray tracing and integral imaging principles. The effectiveness of the proposed method is validated through experiments, and the depth resolution is analyzed in detail. The results show that in a specific light field system, the depth resolution decreases with increasing depth.