High-volume tunable resonator for axion searches above 7 GHz

Taj A. Dyson,Chelsea L. Bartram,Ashley Davidson,Jonah B. Ezekiel,Laura M. Futamura,Tongtian Liu,and Chao-Lin Kuo
DOI: https://doi.org/10.1103/physrevapplied.21.l041002
IF: 4.6
2024-04-24
Physical Review Applied
Abstract:We present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l ( 41λ3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM010 mode is clearly identified with a room-temperature quality factor, Q , of approximately 5000 . The on-resonance E -field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V≫λ3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity. https://doi.org/10.1103/PhysRevApplied.21.L041002 © 2024 American Physical Society
physics, applied
What problem does this paper attempt to address?