Leadless Pacemaker Implantation from the Jugular Vein Ipsilateral to the Dialysis Catheter: Last Resort for Patients with Limited Vascular Routes

Yuto Iioka,Hiro Yamasaki,Tomoko Ishizu
DOI: https://doi.org/10.1016/j.cjca.2024.03.006
IF: 6.614
2024-03-17
Canadian Journal of Cardiology
Abstract:In patients with end-stage renal disease (ESRD), bloodstream infections and vascular access problems are frequently encountered, and patient management is critical if a cardiac implantable electronic device (CIED) infection develops in a pacing-dependent patient. Here, we describe a case of an ESRD patient with a device infection in whom a leadless pacemaker (LP) implantation from the jugular vein ipsilateral to the dialysis catheter (DC) was successful.
cardiac & cardiovascular systems
What problem does this paper attempt to address?