Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

Y P Opachich,R F Heeter,M A Barrios,E M Garcia,R S Craxton,J A King,D A Liedahl,P W McKenty,M B Schneider,M J May,R Zhang,P W Ross,J L Kline,A S Moore,J L Weaver,K A Flippo,T S Perry
DOI: https://doi.org/10.1063/1.4985076
Abstract:Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ∼20 μm thickness have been performed. X-ray yields of up to ∼1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ∼100 μm FWHM, with ∼350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.
What problem does this paper attempt to address?