PMUT-Based System for Continuous Monitoring of Bolted Joints Preload

Stefano Sanvito,Marco Passoni,Domenico Giusti,Marco Terenzi,Carlo Prelini,Monica La Mura,Alessandro Stuart Savoia
DOI: https://doi.org/10.3390/s24134150
IF: 3.9
2024-06-27
Sensors
Abstract:In this paper, we present a bolt preload monitoring system, including the system architecture and algorithms. We show how Finite Element Method (FEM) simulations aided the design and how we processed signals to achieve experimental validation. The preload is measured using a Piezoelectric Micromachined Ultrasonic Transducer (PMUT) in pulse-echo mode, by detecting the Change in Time-of-Flight (CTOF) of the acoustic wave generated by the PMUT, between no-load and load conditions. We performed FEM simulations to analyze the wave propagation inside the bolt and understand the effect of different configurations and parameters, such as transducer bandwidth, transducer position (head/tip), presence or absence of threads, as well as the frequency of the acoustic waves. In order to couple the PMUT to the bolt, a novel assembly process involving the deposition of an elastomeric acoustic impedance matching layer was developed. We achieved, for the first time with PMUTs, an experimental measure of bolt preload from the CTOF, with a good signal-to-noise ratio. Due to its low cost and small size, this system has great potential for use in the field for continuous monitoring throughout the operative life of the bolt.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper aims to address the issue of continuous monitoring of bolt pre-tightening force. Specifically, the paper proposes a system based on Piezoelectric Micromechanical Ultrasonic Transducers (PMUT) for continuous monitoring of the pre-tightening force of bolt connections. By detecting the change in the time of flight of sound waves (CTOF) generated by the PMUT under no-load and load conditions, the system can measure the pre-tightening force of the bolt. Additionally, to couple the PMUT with the bolt, researchers developed a new assembly process that includes depositing an elastic acoustic impedance matching layer on the bolt surface. Due to its low cost and miniaturization, the system has great potential for continuous monitoring throughout the entire service life of the bolt.