Influence of high temperature on the performance of aerobic granular sludge in biological treatment of wastewater

Mohd Hakim Ab Halim,Aznah Nor Anuar,Nur Syahida Abdul Jamal,Siti Izaidah Azmi,Zaini Ujang,Mustafa M Bob
DOI: https://doi.org/10.1016/j.jenvman.2016.09.079
2016-12-15
Abstract:The effect of temperature on the efficiency of organics and nutrients removal during the cultivation of aerobic granular sludge (AGS) in biological treatment of synthetic wastewater was studied. With this aim, three 3 L sequencing batch reactors (SBRs) with influent loading rate of 1.6 COD g (L d)-1 were operated at different high temperatures (30, 40 and 50 °C) for simultaneous COD, phosphate and ammonia removal at a complete cycle time of 3 h. The systems were successfully started up and progressed to steady state at different cultivation periods. The statistical comparison of COD, phosphate and ammonia for effluent from the three SBRs revealed that there was a significant difference between groups of all the working temperatures of the bioreactors. The AGS cultivated at different high temperatures also positively correlated with the accumulation of elements including carbon, oxygen, phosphorus, silicon, iron, aluminium, calcium and magnesium that played important roles in the granulation process.
What problem does this paper attempt to address?