Echocardiographic surrogate of left ventricular stroke work in a model of brain stem death donors
Kei Sato,Louise See Hoe,Jonathan Chan,Nchafatso G. Obonyo,Karin Wildi,Silver Heinsar,Sebastiano M. Colombo,Carmen Ainola,Gabriella Abbate,Noriko Sato,Margaret R. Passmore,Mahe Bouquet,Emily S. Wilson,Kieran Hyslop,Samantha Livingstone,Andrew Haymet,Jae‐Seung Jung,Kris Skeggs,Chiara Palmieri,Nicole White,David Platts,Jacky Y. Suen,David C. McGiffin,Gianluigi Li Bassi,John F. Fraser
DOI: https://doi.org/10.1111/eci.14259
2024-06-08
European Journal of Clinical Investigation
Abstract:A novel Speckle‐tracking echocardiographic parameter, pressure‐strain product, showed a correlation with LVSWI and myocyte mitochondrial function. C1 + 2, Complex1 + 2; GCS, global circumferential strain; LV, left ventricular; LVSWI, left ventricular stroke work index; MAP, mean arterial pressure; PSPcirc, pressure‐strain product based on circumferential strain; SGC, Swan‐Ganz catheter (Images were created by using Biorender.com). Background The commonest echocardiographic measurement, left ventricular ejection fraction, can not necessarily predict mortality of recipients following heart transplantation potentially due to afterload dependency. Afterload‐independent left ventricular stroke work index (LVSWI) is alternatively recommended by the current guideline; however, pulmonary artery catheters are rarely inserted in organ donors in most jurisdictions. We propose a novel non‐invasive echocardiographic parameter, Pressure‐Strain Product (PSP), as a potential surrogate of catheter‐based LVSWI. This study aimed to investigate if PSP could correlate with catheter‐based LVSWI in an ovine model of brain stem death (BSD) donors. The association between PSP and myocardial mitochondrial function in the post‐transplant hearts was also evaluated. Methods Thirty‐one female sheep (weight 47 ± 5 kg) were divided into two groups; BSD (n = 15), and sham neurologic injury (n = 16). Echocardiographic parameters including global circumferential strain (GCS) and global radial strain (GRS) and pulmonary artery catheter‐based LVSWI were simultaneously measured at 8‐timepoints during 24‐h observation. PSP was calculated as a product of GCS or GRS, and mean arterial pressure for PSPcirc or PSPrad, respectively. Myocardial mitochondrial function was evaluated following 6‐h observation after heart transplantation. Results In BSD donor hearts, PSPcirc (n = 96, rho = .547, p
medicine, general & internal, research & experimental