Effects of Hydrogen Blending Ratio and Equivalence Ratio on the Dynamic Characteristics of Deflagration Shock Waves of CH 4 /H 2 Mixtures

Qiqi Liu,Zhenyi Liu,Shiyao Peng,Chuang Liu,Changqi Liu,Luoqian Liu,Rui Zhou,Shujie Zhi,Tao Fan,Pengliang Li
DOI: https://doi.org/10.1021/acsomega.4c01876
IF: 4.1
2024-06-11
ACS Omega
Abstract:To evaluate the explosion hazard of CH(4)/H(2) mixtures, experiments were conducted in a long and closed pipeline with a length-to-diameter ratio of 51 and built-in obstacles, and the characteristic parameters of deflagration shock waves were analyzed under different hydrogen blending ratios (0 ≤ λ ≤ 100%) and equivalence ratios (0.5 ≤ Φ ≤ 3). The results indicate that within the range of Φ = 0.8-1.2, the explosion overpressure (P (P)) exhibits a "two-zone" structure distribution. When 0 ≤ λ ≤...
chemistry, multidisciplinary
What problem does this paper attempt to address?