High-Throughput Detection of Risk Factors to Sudden Cardiac Arrest in Youth Athletes: A Smartwatch-Based Screening Platform

Evan Xiang,Thomas Wang,Vivan Poddar
2024-12-03
Abstract:Sudden Cardiac Arrest (SCA) is the leading cause of death among athletes of all age levels worldwide. Current prescreening methods for cardiac risk factors are largely ineffective, and implementing the International Olympic Committee recommendation for 12-lead ECG screening remains prohibitively expensive. To address these challenges, a preliminary comprehensive screening system (CSS) was developed to efficiently and economically screen large populations for risk factors to SCA. A protocol was established to measure a 4-lead ECG using an Apple Watch. Additionally, two key advances were introduced and validated: 1) A decomposition regression model to upscale 4-lead data to 12 leads, reducing ECG cost and usage complexity. 2) A deep learning model, the Transformer Auto-Encoder System (TAES), was designed to extract spatial and temporal features from the data for beat-based classification. TAES demonstrated an average sensitivity of 95.3% and specificity of 99.1% respectively in the testing dataset, outperforming human physicians in the same dataset (Se: 94%, Sp: 93%). Human subject trials (n = 30) validated the smartwatch protocol, with Bland-Altman analysis showing no statistical difference between the smartwatch vs. ECG protocol. Further validation of the complete CSS on a 20-subject cohort (10 affected, 10 controls) did not result in any misidentifications. This paper presents a mass screening system with the potential to achieve superior accuracy in high-throughput cardiac pre-participation evaluation compared to the clinical gold standard.
Signal Processing,Machine Learning
What problem does this paper attempt to address?
### What problem does this paper attempt to solve? This paper aims to solve the problem of screening risk factors for sudden cardiac arrest (SCA) among young athletes. Specifically, the current pre - screening methods for cardiac risk factors are not effective. In particular, the 14 - point questionnaire pre - participation evaluation (Pre - participation Evaluation, PPE) recommended by the American Heart Association (AHA) has low sensitivity and specificity (18.8% and 68.0% respectively). In addition, although the 12 - lead electrocardiogram (12 - lead ECG) screening recommended by the International Olympic Committee is regarded as the gold standard by the European Society of Cardiology, it is too costly to implement and complex to operate. To solve these problems, the author has developed a high - throughput screening system (Comprehensive Screening System, CSS) based on smartwatches to screen SCA risk factors on a large scale in an efficient and economical way. The main innovations of this system include: 1. **Data Dimensionality - increasing Algorithm**: The 4 - lead electrocardiogram data is increased to 12 - lead by the decomposition regression model, thus reducing the cost and usage complexity of ECG. 2. **Deep Learning Model**: A Transformer Auto - Encoder System (TAES) is designed to extract spatio - temporal features from data and perform beat - by - beat classification. The average sensitivity of TAES in the test dataset is 95.3% and the specificity is 99.1%, which is better than the performance of human doctors in the same dataset (sensitivity 94%, specificity 93%). In addition, this study also carried out a human trial (n = 30) and verified through Bland - Altman analysis that there is no statistical difference between the smartwatch protocol and the traditional ECG protocol. Further verification shows that the complete CSS has no misjudgment in a cohort of 20 subjects (10 case groups and 10 control groups). In conclusion, this paper proposes a large - scale cardiac pre - participation evaluation system with high throughput and high accuracy, which is expected to replace the clinical gold standard in the future.