Development and Multinational Validation of an Ensemble Deep Learning Algorithm for Detecting and Predicting Structural Heart Disease Using Noisy Single-lead Electrocardiograms

Arya Aminorroaya,Lovedeep Singh Dhingra,Aline Pedroso Camargos,Sumukh Vasisht Shankar,Andreas Coppi,Akshay Khunte,Murilo Foppa,Luisa Campos Caldeira Brant,Sandhi Maria Barreto,Antonio L. P. Ribeiro,Harlan Krumholz,Evangelos K Oikonomou,Rohan Khera
DOI: https://doi.org/10.1101/2024.10.07.24314974
2024-10-08
Abstract:Background and Aims: AI-enhanced 12-lead ECG can detect a range of structural heart diseases (SHDs) but has a limited role in community-based screening. We developed and externally validated a noise-resilient single-lead AI-ECG algorithm that can detect SHD and predict the risk of their development using wearable/portable devices. Methods: Using 266,740 ECGs from 99,205 patients with paired echocardiographic data at Yale New Haven Hospital, we developed ADAPT-HEART, a noise-resilient, deep-learning algorithm, to detect SHD using lead I ECG. SHD was defined as a composite of LVEF<40%, moderate or severe left-sided valvular disease, and severe LVH. ADAPT-HEART was validated in four community hospitals in the US, and the population-based cohort of ELSA-Brasil. We assessed the model's performance as a predictive biomarker among those without baseline SHD across hospital-based sites and the UK Biobank. Results: The development population had a median age of 66 [IQR, 54-77] years and included 49,947 (50.3%) women, with 18,896 (19.0%) having any SHD. ADAPT-HEART had an AUROC of 0.879 (95% CI, 0.870-0.888) with good calibration for detecting SHD in the test set, and consistent performance in hospital-based external sites (AUROC: 0.852-0.891) and ELSA-Brasil (AUROC: 0.859). Among those without baseline SHD, high vs. low ADAPT-HEART probability conferred a 2.8- to 5.7-fold increase in the risk of future SHD across data sources (all P<0.05). Conclusions: We propose a novel model that detects and predicts a range of SHDs from noisy single-lead ECGs obtainable on portable/wearable devices, providing a scalable strategy for community-based screening and risk stratification for SHD.
Cardiovascular Medicine
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to detect and predict structural heart disease (SHD) using single - lead electrocardiograms (ECG) obtained from portable or wearable devices in a community environment. Currently, although 12 - lead electrocardiograms can detect a variety of structural heart diseases in a clinical environment, their application scope is limited, especially in community screening. The main challenge lies in the lack of a feasible screening strategy that can be deployed in large - scale populations and does not require advanced imaging or detailed medical evaluations. In addition, currently, the diagnosis of SHD usually requires referral for echocardiography or other advanced cardiac imaging examinations, and there is no specific guidance on which asymptomatic patients should be referred. The paper proposes a new method by developing and validating a noise - resistant deep - learning algorithm (ADAPT - HEART), which can detect and predict SHD from single - lead electrocardiograms obtained from portable or wearable devices. Specifically, this algorithm aims to identify composite indicators of SHD such as left ventricular ejection fraction (LVEF) < 40%, moderate or severe left - sided valvular disease, and severe left ventricular hypertrophy (sLVH). Through this method, researchers hope to provide a scalable community - screening and risk - stratification strategy to detect SHD earlier, thereby improving patients' treatment outcomes and prognoses.