Nutzung von Massespeichern zur Flexibilisierung des Energieverbrauchs: Kosteneffizienter Anlagenbetrieb durch Anpassung an Marktpreise

Lukas Peter Wagner,Lasse Matthias Reinpold,Maximilian Kilthau,Felix Gehlhoff,Christian Derksen,Nils Loose,Julian Jepsen,Alexander Fay
2024-11-28
Abstract:The increasing share of renewable energy sources and necessitate new concepts for energy flexible operation of industrial production resources. In this paper, we demonstrate the potential of mass storage to increase energy flexibility in industrial operations through the application of optimized operational planning based on market prices. A wastewater treatment plant equipped with decanters and storages is examined to optimally utilize its energy-flexibility. An MILP model was created for energy-flexible production facilities. The resulting operation plan was transmitted to the plant operators and executed over a period of more than 24 hours. The model shows good agreement with real measurements (average errors between 3% to 7%). The results demonstrate significant potential for cost savings of roughly 56% for the investigated time horizon. -- Der zunehmende Anteil erneuerbarer Energien erfordert neue Konzepte zur energieflexiblen Steuerung industrieller Produktionsanlagen. In diesem Beitrag wird demonstriert, wie das Potenzial von Massespeichern zur Steigerung der Energieflexibilität in industriellen Prozessen durch die Anwendung optimierter Betriebsplanung basierend auf Marktpreisen, genutzt werden kann. Es wird eine Abwasseraufbereitungsanlage mit Dekantern und zugehörigen Massespeichersystemen betrachtet, um deren Energieflexibilität optimiert zu nutzen. Der resultierende Betriebsplan wurde in einem Assistenzsystem an die Anlagenbetreiber übermittelt und über einen Zeitraum von über 24 Stunden ausgeführt. Das Modell zeigt eine gute Übereinstimmung mit den realen Messwerten (Fehlern zwischen 3% und 7%). Alle von den Betreibern gesetzten Betriebsziele wurden erreicht, was die Anwendbarkeit des Modells in industriellen Umgebungen bestätigt. Die Ergebnisse zeigen ein erhebliches Einsparpotenzial von etwa 56% für den untersuchten Zeitraum.
Systems and Control
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to solve the problems of energy production and consumption flexibility brought about by the increasing proportion of renewable energy. Specifically, the paper explores how to improve energy flexibility and reduce costs by optimizing the operation plans of industrial production facilities, especially by using mass storage systems (such as sludge bags and containers) in wastewater treatment plants. #### Main research questions: 1. **Improvement of energy flexibility**: How to improve the energy flexibility of industrial processes (especially wastewater treatment plants) by optimizing operation plans and using mass storage systems. 2. **Cost - effective operation**: How to achieve more economical and efficient plant operation by responding to market prices. 3. **Verification of practical applications**: Verify the validity and applicability of the optimization model in a real - industrial environment and show its energy - saving potential. #### Specific cases: Taking a wastewater treatment plant equipped with a Dekanter and related mass storage systems as an example, the paper shows how to maximize energy flexibility by optimizing the operation plan. For this purpose, a mixed - integer linear programming (MILP) optimization model was developed and tested in a real - field trial to minimize the electricity cost of the wastewater treatment plant. #### Research objectives: - **Development and verification of the optimization model**: Develop an optimization model that can adapt to market price fluctuations and verify its performance in practical applications. - **Assessment of energy - saving potential**: Evaluate the cost - saving potential that can be achieved through flexible operation methods. - **Feasibility of industrial applications**: Confirm the feasibility and effectiveness of the optimization model in an industrial environment. #### Results: The experimental results show that the optimized operation plan has a good consistency with the actual measured values, with an average error between 3% and 7%. All the set operation goals were achieved, verifying the applicability of the model in an industrial environment. The results indicate that the cost - saving potential is approximately 56% within the studied time period. #### Key formulas: - Range of operating points: \[ OP_{\text{min}} \leq OP_t \leq OP_{\text{max}} \] - Calculation of electric power: \[ P_{\text{el},t} = a \cdot x_{\text{Betrieb},t} + b \cdot OP_t + c \cdot T_{\text{trocken},t} \cdot x_{\text{Betrieb},t} + d \cdot x_{\text{Start},t} \] - Energy balance: \[ SOC_t = SOC_{t - 1}+(P_{\text{in},t} - P_{\text{out},t}) \cdot \Delta t \] - Objective function: \[ \min \text{Kosten}=\sum_{t \in T} P_{\text{System},t} \cdot \Delta t \cdot k_{\text{el},t} \] Through these methods and models, the paper successfully shows how to improve energy flexibility and reduce costs by optimizing operation plans in an industrial environment.