Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

E. S. Martsen,P. S. Barry,B. A. Benson,K. R. Dibert,K. N. Fichman,T. Natoli,M. Rouble,C. Yu
2024-11-27
Abstract:SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to ensure the precise distribution of the resonance frequencies of 34,000 microwave kinetic - inductance detectors (MKIDs) in the SPT - 3G+ camera, in order to avoid resonance - frequency collisions and improve the overall yield of the detectors. Specifically: 1. **Resonance - frequency precision control**: Each read - out line needs to measure 800 MKIDs within a 500 - MHz bandwidth, which requires very precise control of the resonance frequency of each MKID to avoid collisions between resonance frequencies, thereby reducing the number of ineffective detectors. 2. **Optical mapping and spectrum adjustment**: To solve the above problems, the researchers developed a two - step method: - **Optical mapping**: Use an LED device to map the resonance frequencies to physical pixel positions. - **Capacitance trimming**: Fine - tune the resonance frequencies by adjusting the inter - digitized capacitor (IDC) to meet the design requirements. 3. **Testing in a low - temperature environment**: To simulate actual working conditions, the researchers developed an LED mapping device that can operate in a 300 - mK low - temperature environment and successfully integrated it with the GHz read - out electronics system (RF - ICE) for characterizing the prototype SPT - 3G+ detector array. ### Main challenges - **Resonance scattering**: Due to inconsistencies in the manufacturing process, the actual resonance frequency of an MKID may deviate from the design value, resulting in resonance - frequency collisions or misalignments, thereby rendering some detectors ineffective. - **High - density integration**: Integrating a large number of detectors in a limited space requires precise control of the frequency spacing of each detector to achieve efficient multiplexed read - out. Through these methods, the researchers hope to significantly improve the yield and performance of detectors in future SPT - 3G+ cameras, thereby better measuring the cosmic microwave background (CMB) and other important astronomical phenomena.