Experimental demonstration of dark current mitigation by an over-inserted plug in a normal conducting VHF gun

X.-H. Wang,G. Shu,H. Qian,X. Li,Z. Liu,Z. Jiang,H. Meng,C. Xing,Q. Zhou,H. Deng
2024-11-04
Abstract:The room temperature continuous wave (CW) very-high-frequency (VHF) gun is one of the candidates for the electron gun of the high-repetition-rate free-electron lasers (FELs). The VHF gun operates with a cathode gradient of ~ 20 MV/m and an accelerating voltage of ~ 750 kV. The gun dark current emission leads to beam loss along the FEL machine, therefore is a critical parameter for the performance of the CW gun. In this paper, we presents a systematic study of the dark current reduction of the VHF gun, including cathode region optimizations, dark current tracking simulations and measurements. Over-inserted cathode plugs were tested in two VHF guns of different acceleration gap sizes, and both demonstrated significant dark current reduction ratios of more than two orders of magnitude.
Accelerator Physics
What problem does this paper attempt to address?